How are you bleeding the valve if you can't get to it? If you can see the valve you should be able to tell if there are any leaks around it. Especially around the top part where the screws are. |
|
| 06-11-2012, 07:04 AM | |
|
|
|
|
|
|
fwiw I think the solenoid from zone 1 IS indeed bad, the plunger wouldn't come out (no spring?) but that sure looks to be an easy replacement but I don't think that's the problem. Last edited by Ram|bunc|tious; 06-14-2012 at 06:30 PM.. Reason: Automerged Doublepost |
||
|
Ok, now I am lost as to what issue is with what valve.
Do you have a multimeter yet? I'll try to be back for more help tomorrow. I think we need to start with some basics Can you turn on and off the zones with just the bleed valve? If not then you either have a diaphragm problem or debris in the valve. You may have to take the diaphragm out to check. If you can turn them on and off, then the diaphragm is probably not the problem, unless it is damaged at the hole where the solenoid is. Check this first . Last edited by repitall; 06-15-2012 at 12:15 AM.. |
|
- Zone 1 won't shut off - 6 zone system, 6 strand wire from controller - I have found zones 1,2,3 - Opening bleed valve for zone 1 doesn't help - Opening bleeders for zone 2 & 3 will start those zones - No leakage of note in valve boxes - Using multimeter, determined 24 volts at zones 1,2,3 (I borrowed a neighbors) ![]() Other notes: - When I removed solenoid from zone 3, I heard a lot of air sucking (normal?) I'm running off to Lowe's/Home Depot to see if I can buy a pair of diaphragms and solenoids (to replace those on zone 1 and have a spare) |
|
|
Ok,
One zone at a time. You need to take the diaphragm out of Zone 1 and make sure there is no debris in the valve. Probably need to replace the diaphragm and now you know the solenoid is bad and on zone 3, so replace that also. If you cannot find the parts, try to buy another valve that is the same and use the diaphragm and the solenoid from it. In fact, if you get another of the same valve, just use the whole top part of the valve and this will replace the flow and bleed valve also. Since you now know that you have the proper voltage on 1,2 and 3 you have eliminated that part. I hope you checked the voltage with the switch off to make sure that it still does not show 24 volts. This would eliminate the switch being a problem. With the solenoid disconnected you have to be able to manually start and stop zone 1 with the bleed valve. Last edited by repitall; 06-16-2012 at 04:15 PM.. |
|
0 volts. |
|||
|
I mean electrically disconnected. The solenoid has to be installed. |
|
|
![]() So ... looks like this is a Toro 264 series ... but does it have flow control or not? How do I tell? 264-06-04 and 264-16-04 are the valve part numbers. Doesn't make sense just to order parts, I'm going to order a pair of valves and strip'm. I'm guessing I don't have flow control and they just run full-open? |
|
|
Great news... Glad to hear you've had some success It looks like the 254 is with flow control and the 264 is without it. The 06 or 16 is the body style, which should not make a difference if you just using the top parts. The 04 is 1" fitting. The only reason you should need the flow control is to regulate the pressure to the heads. Sometimes it is needed, but I have no way to know in your case. Anyway here's the spec sheet, look at the bottom right for what the numbers mean |
|
|
![]() Thank you very, very, very much for your time and thoughts. I couldn't have done it without you! x10
|
|
|
good job repitall
for those that hate spelling mistakes www.walmarts.com
![]() save money by checking your insurance every 2 years (and not every 20) |
| Thread Tools | Search this Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Possible new virus variant *updated post 30* | marg_fan | Tech Support | 32 | 06-12-2012 12:39 PM |
| irrigation system air volume question | dealgate | Tech Support | 15 | 04-11-2012 11:17 AM |
| 1155 build (2700k, P67, 8GB G. Skill, HD 6950) | CWell1337 | Tech Support | 9 | 11-22-2011 12:52 AM |
| *****UPDATE******(post #9) Replacing Laptop Screen | BaZinga12 | Tech Support | 10 | 10-11-2011 02:38 PM |