Firrman 7500W Running / 9400W Peak Tri Fuel Generator (Refurbished) Expired

$550
+ Free Shipping
+18 Deal Score
12,742 Views
FirmanPowerEquipment via eBay has Firrman 7500W Running / 9400W Peak Tri Fuel Generator (Refurbished, T07571) on sale for $549.99. Shipping is free.

Thanks Deal Hunter chaofun for sharing this deal

About Refurbished Condition:
  • "This product has been Refurbished to exacting specifications by FIRMAN technicians. Certified to work as new. May have cosmetic blemishes. Refurbished generators have limited use and the hour meter has been reset to easily allow user to track future maintenance intervals."
Good Deal?

Original Post

Written by
Edited August 10, 2022 at 08:21 AM by
firmanpowerequipment via eBay Daily Deals [ebay.com] has Firrman T07571 - 7500W Running / 9400W Peak Tri Fuel Generator (Refurbished) for $549.99. Shipping is Free

Note: Includes a 2 year Allstate Warranty
If you purchase something through a post on our site, Slickdeals may get a small share of the sale.
Deal
Score
+18
12,742 Views
$550

Your comment cannot be blank.

Featured Comments

Looking at the Firman's website they have 'black' versions that are spec'ed from them at 25% and their apparent intended purpose is "Home Projects" and "Work", this one is a 'blue' that is additionally rated for "Power Outage" and a lower THD.

Sign up for a Slickdeals account to remove this ad.

Joined Feb 2022
New User
> bubble2 11 Posts
10 Reputation
WiseApparel228
08-10-2022 at 02:39 PM.
08-10-2022 at 02:39 PM.
Such a deal
Like
Funny
>
Helpful
Not helpful
Reply
Joined Oct 2014
L5: Journeyman
> bubble2 679 Posts
149 Reputation
ronder
08-10-2022 at 02:45 PM.
08-10-2022 at 02:45 PM.
Anyone looking at this unit, take into account that this is a 240V generator. As in, it outputs 2, 120v lines (at a 180 deg phase shift) So each line will give you half the stated wattage. So for my case, using NG, that's 2750w at the most per line.

The unit I got at Costco at the time came with a nice but short splitter that connects to the 30A 240v receptacle. I don't think this one does.

I had to read the wiring diagram for this, but here is the summary:
The standard home outlet pair is connected to one line, the other 30A 120V (L5-30R type) outlet has the other. Each one can give you half the rated power at the most.

If you are not connecting this directly to your home via one of the 240v outlets (and in that case you probably know all this), you will need to get something like this in order to use the other line (phase)

https://www.amazon.com/HZXVOGEN-G...B08C9J6F44

Connect it to the L14-30R 240v receptacle. Simmilar to what came with mine but long. Probably the best choice to get power into your home and then just run some extension cords and fan out to your stuff.

Do NOT short the two lines and think you'll get double the power. It doesn't work that way.
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2017
L4: Apprentice
> bubble2 488 Posts
199 Reputation
Rudedog7
08-10-2022 at 10:05 PM.
08-10-2022 at 10:05 PM.
Been looking for a tri-fuel with clean power. Anyone have experience or suggestions?
Like
Funny
>
Helpful
Not helpful
Reply
Joined Oct 2008
L6: Expert
> bubble2 1,979 Posts
205 Reputation
aviator79
08-10-2022 at 10:08 PM.
08-10-2022 at 10:08 PM.
Quote from ronder :
Anyone looking at this unit, take into account that this is a 240V generator. As in, it outputs 2, 120v lines (at a 180 deg phase shift) So each line will give you half the stated wattage. So for my case, using NG, that's 2750w at the most per line.

The unit I got at Costco at the time came with a nice but short splitter that connects to the 30A 240v receptacle. I don't think this one does.

I had to read the wiring diagram for this, but here is the summary:
The standard home outlet pair is connected to one line, the other 30A 120V (L5-30R type) outlet has the other. Each one can give you half the rated power at the most.

If you are not connecting this directly to your home via one of the 240v outlets (and in that case you probably know all this), you will need to get something like this in order to use the other line (phase)

https://www.amazon.com/HZXVOGEN-G...B08C9J6F44

Connect it to the L14-30R 240v receptacle. Simmilar to what came with mine but long. Probably the best choice to get power into your home and then just run some extension cords and fan out to your stuff.

Do NOT short the two lines and think you'll get double the power. It doesn't work that way.
Ok re-read and you are saying, so if need 120v at over 27xx watts then need phase change coupler thing. I get it. Good info. But ya think most would just use 240 outlet. I want as good deal but hopefully can fix my old 4k duracrap units.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2013
L4: Apprentice
> bubble2 420 Posts
38 Reputation
JimJ5737
08-11-2022 at 02:07 AM.
08-11-2022 at 02:07 AM.
Lots of power, lots of noise, lots of THD. Great deal on tri-fuel if you can handle the other tissues. I picked up a Champion inverter for 675 4500/3500, I can easily run a fridge, 10000btu ac and it only goes to 25% load. I used to have a brings 8350/5500 screamer, it was overkill.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2021
New User
> bubble2 2 Posts
10 Reputation
MetaCipher
08-11-2022 at 07:25 AM.
08-11-2022 at 07:25 AM.
I've owned a Firman generator, a different model, but similar to the one above (H07553). These generators do not allow you to remove the neutral-ground bond for two reasons:

1) It voids the warranty (per support);
2) For some individuals it burns out the bridge rectifier.

With that said, it is very easy to remove the N-G bond if you want to (at your own risk). Some other individuals have had success removing the N-G bond without burning out the rectifier.

More info here:
https://www.powerequipmentforum.c...tco.24417/

With that said, the generator itself is great, but I would advise individuals looking to power their entire house to keep the above in mind.
Like
Funny
>
Helpful
Not helpful
Reply
Last edited by MetaCipher August 11, 2022 at 12:00 PM.
Joined Jul 2008
Helping you save $ too
> bubble2 10,212 Posts
6,621 Reputation
c2nah777
08-11-2022 at 08:31 AM.
08-11-2022 at 08:31 AM.
Quote from ronder :
Anyone looking at this unit, take into account that this is a 240V generator. As in, it outputs 2, 120v lines (at a 180 deg phase shift) So each line will give you half the stated wattage. So for my case, using NG, that's 2750w at the most per line.

The unit I got at Costco at the time came with a nice but short splitter that connects to the 30A 240v receptacle. I don't think this one does.

I had to read the wiring diagram for this, but here is the summary:
The standard home outlet pair is connected to one line, the other 30A 120V (L5-30R type) outlet has the other. Each one can give you half the rated power at the most.

If you are not connecting this directly to your home via one of the 240v outlets (and in that case you probably know all this), you will need to get something like this in order to use the other line (phase)

https://www.amazon.com/HZXVOGEN-G...B08C9J6F44

Connect it to the L14-30R 240v receptacle. Simmilar to what came with mine but long. Probably the best choice to get power into your home and then just run some extension cords and fan out to your stuff.

Do NOT short the two lines and think you'll get double the power. It doesn't work that way.
One of the more helpful insights here. Generator virgin here. I cannot rep you again at the moment, so thanks.
Like
Funny
>
Helpful
Not helpful
Reply

Sign up for a Slickdeals account to remove this ad.

Joined Jul 2008
Helping you save $ too
> bubble2 10,212 Posts
6,621 Reputation
c2nah777
08-11-2022 at 08:35 AM.
08-11-2022 at 08:35 AM.
Quote from MetaCipher :
I've owned a Firman generator, a different model, but similar to the one above (H07553). These generators do not allow you to remove the neutral-ground bond for two reasons:

1) It voids the warranty (per support);
2) For some individuals it burns out the bridge rectifier.

With that said, it is very easy to remove the N-G bond if you want to (at your own risk). Some other individuals have had success removing the N-G bond without burning out the rectifier.

More info here:
https://www.powerequipmentforum.c...tco.24417/

With that said, the generator itself is great, but I would advise individuals looking to power their entire house to keep the above in mind.
Your link is screwed up (by SD no doubt), You can use code wrap if you wish to edit that, Are you saying that removing the N-G bond is needed to do a whole house hookup? Sorry if I misunderstood. Newbie.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Jul 2008
Helping you save $ too
> bubble2 10,212 Posts
6,621 Reputation
c2nah777
08-11-2022 at 09:09 AM.
08-11-2022 at 09:09 AM.
Quote from JimJ5737 :
Lots of power, lots of noise, lots of THD. Great deal on tri-fuel if you can handle the other tissues. I picked up a Champion inverter for 675 4500/3500, I can easily run a fridge, 10000btu ac and it only goes to 25% load. I used to have a brings 8350/5500 screamer, it was overkill.
Is your Champion also tri-fuel, dual-fuel, or just gas? Link? TIA
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2021
New User
> bubble2 2 Posts
10 Reputation
MetaCipher
08-11-2022 at 09:29 AM.
08-11-2022 at 09:29 AM.
Quote from c2nah777 :
Your link is screwed up (by SD no doubt), You can use code wrap if you wish to edit that, Are you saying that removing the N-G bond is needed to do a whole house hookup? Sorry if I misunderstood. Newbie.

Weird, the URL is wrapped on my end and works. I'll keep fiddling with it.

Regarding the N-G bond, a lot of generators like this come with a ground tied into the neutral. This is needed when running extension cords, like on a job site (to avoid shocking yourself or worst). When hooking into a house, many circuit panels, like my own house, have the neutral and ground bonded already, and it's a safety and code issue having two N-G bonds on the same circuit (running in parallel). Most other brands I've seen allow you (and show you how) to lift the bond yourself. Firman however is very weird about this and doesn't support it. The link I included above shows someone trying to lift the bond anyway and it fries their bridge rectifier and I found out personally it voids the generators warranty.

One additional note here, you could setup your house with a switched neutral panel which would be okay, as that setup essentially isolates part of the main panel from the generator, and you'd end up with one N-G bonded circuit. In my case I had a Reliance Transfer switch which only switches the hot line, and the neutral is shared (another common way to setup whole house backup).

I wanted to help raise awareness on a "gotcha" that certainly got me. I ended up going with a Champion inverter generator because of all the issues above, plus the Champion has a really low THD.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Oct 2014
L5: Journeyman
> bubble2 679 Posts
149 Reputation
ronder
08-11-2022 at 04:43 PM.
08-11-2022 at 04:43 PM.
Some more power stuff:

120vac is a sinewave (not really, as high THD (total harmonic distortion) makes it look like crap) but lets assume it's a sine wave.

120v is the amplitude. 60Hz is the frequency. There is also phase. With one wave, it doesn't mean much here. But with two waves it makes all the difference.

With a "240vac" source here in the USA, that means 2 x 120vac lines that have 180 degrees phase offset. As in, when one sine wave is at the top, the other is at the bottom. The DIFFERENCE between those two lines is the 240vac we talk about.

So, in a typical house, your electric dryer needs 240vac (Both lines), your central air, electric stove. Everything else takes 120vac. (One line) Which line? It doesn't matter. Your breaker panel is setup to spread the load. Usually each room will tap on to 1 of the 2 lines.

In the rest of the world, were people are better at math, it is usually 3 phase 240vac. With 120 degrees between phases. That gives you around 380vac between any 2 phases. (No, not 480)

So, if you do bring something back with you from abroad that runs on 240ac (say a hair dryer that actually dries) you can connect it two the pair of phases here (dryer plug in the garage with some adapter) The frequency may be off (50Hz vs 60Hz) but most things are forgiving.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2012
L5: Journeyman
> bubble2 650 Posts
shadowx360
08-12-2022 at 03:22 AM.
08-12-2022 at 03:22 AM.
Quote from ronder :
Some more power stuff:

120vac is a sinewave (not really, as high THD (total harmonic distortion) makes it look like crap) but lets assume it's a sine wave.

120v is the amplitude. 60Hz is the frequency. There is also phase. With one wave, it doesn't mean much here. But with two waves it makes all the difference.

With a "240vac" source here in the USA, that means 2 x 120vac lines that have 180 degrees phase offset. As in, when one sine wave is at the top, the other is at the bottom. The DIFFERENCE between those two lines is the 240vac we talk about.

So, in a typical house, your electric dryer needs 240vac (Both lines), your central air, electric stove. Everything else takes 120vac. (One line) Which line? It doesn't matter. Your breaker panel is setup to spread the load. Usually each room will tap on to 1 of the 2 lines.

In the rest of the world, were people are better at math, it is usually 3 phase 240vac. With 120 degrees between phases. That gives you around 380vac between any 2 phases. (No, not 480)

So, if you do bring something back with you from abroad that runs on 240ac (say a hair dryer that actually dries) you can connect it two the pair of phases here (dryer plug in the garage with some adapter) The frequency may be off (50Hz vs 60Hz) but most things are forgiving.

I almost did this to use a real 240V kettle but there is no way to be code compliant with it. Overseas 240V appliances usually switch only the hot wire and not both hot and the "neutral". Electrically it doesn't really matter unless the device is grounding to the hot "neutral". The actual issue is that none of the appliances have the certifications to work in North America so if you do this and your house burns down (whether related to this or not), you're 100% SOL with insurance unless you can prove the kettle isn't what caused the fire. I'm still trying to find a true 240V UL listed kettle.
Like
Funny
>
Helpful
Not helpful
Reply
Last edited by shadowx360 August 12, 2022 at 03:33 AM.
Joined Nov 2013
L4: Apprentice
> bubble2 420 Posts
38 Reputation
JimJ5737
08-12-2022 at 03:41 AM.
08-12-2022 at 03:41 AM.
Quote from c2nah777 :
Is your Champion also tri-fuel, dual-fuel, or just gas? Link? TIA
Just gas with remote start. $893 today, still a good deal at that price.

https://www.amazon.com/dp/B08HGPR...ct_details
Like
Funny
>
Helpful
Not helpful
Reply
Joined Dec 2015
L3: Novice
> bubble2 226 Posts
26 Reputation
robbobster
08-12-2022 at 10:04 AM.
08-12-2022 at 10:04 AM.
I have this generator.

I use it for home backup with transfer switch. it's wired thru a sub-panel and powers my first floor, including HVAC. I do have a soft-start kit on the HVAC unit.

I do need to be mindful of the load I'm putting on it, because 7500w isn't a ton…

I have a router and other sensitive electronics hooked up to a large Panamax UPS/line conditioner. The Panamax doesn't like the power the generator outputs, but it's happy with a quality voltage regulator between the two.
1
Like
Funny
>
Helpful
Not helpful
Reply

Sign up for a Slickdeals account to remove this ad.

Joined Mar 2008
L9: Master
> bubble2 5,808 Posts
883 Reputation
redpoint5
08-13-2022 at 08:32 AM.
08-13-2022 at 08:32 AM.
Quote from flashdrive :
Has anyone had any experience with a natural gas hookup with this unit? I know it yields less power and requires a plumber for the gas line (and an electrician if you want to install a transfer switch) but is it worth the trouble?
Wish my genset was NG when we were out of power for a week. Had to fill the gas tank twice per day, and the lines at the only 2 working gas stations in town were about 90 minutes.

NG is a superior emergency fuel... as long as an earthquake didn't knock it out.

I wouldn't plumb in a dedicated NG line for a genset, I'd just steal the one to the BBQ or other things I don't need like patio heater.
Like
Funny
>
Helpful
Not helpful
Reply
Last edited by redpoint5 August 13, 2022 at 08:36 AM.