DuctlessAire 12 Seer 12000 BTU 220V 1-Ton Ductless Mini Split Air Conditioner

+ Free Shipping

$779

Home Depot
169 Comments 82,350 Views
Visit Home Depot
Good Deal
Save
Share
Deal Details
Home Depot has DuctlessAire 12 Seer 12000 BTU 220V 1-Ton Ductless Mini Split Air Conditioner & Heat Pump Variable Speed Inverter w/ WiFi (DA1221-H2) for $779. Shipping is free.

Thanks to community member david3808 for finding this deal.

Included:
  • Copper tubing w/ insulation and nuts
  • Control wire
  • 6' drain hose
  • Wall sleeve
  • Wall sleeve cover and tape

Editor's Notes

Written by CChoiVA
  • About this product:
    • Rated 4.9 stars out of 5 overall based on 900+ reviews on Home Depot
    • 2-direction air vane
    • Built-in electronic diagnostic monitoring
    • Dual washable filters
  • About this store:
    • Home Depot Return Policy may be found here

Original Post

Written by david3808
Community Notes
About the Poster
Deal Details
Community Notes
About the Poster
Home Depot has DuctlessAire 12 Seer 12000 BTU 220V 1-Ton Ductless Mini Split Air Conditioner & Heat Pump Variable Speed Inverter w/ WiFi (DA1221-H2) for $779. Shipping is free.

Thanks to community member david3808 for finding this deal.

Included:
  • Copper tubing w/ insulation and nuts
  • Control wire
  • 6' drain hose
  • Wall sleeve
  • Wall sleeve cover and tape

Editor's Notes

Written by CChoiVA
  • About this product:
    • Rated 4.9 stars out of 5 overall based on 900+ reviews on Home Depot
    • 2-direction air vane
    • Built-in electronic diagnostic monitoring
    • Dual washable filters
  • About this store:
    • Home Depot Return Policy may be found here

Original Post

Written by david3808

Community Voting

Deal Score
+57
Good Deal
Visit Home Depot

Leave a Comment

Unregistered (You)

Top Comments

PlanetoftheMapes
860 Posts
330 Reputation
I bought a 2-head Senville 22 SER unit last month and came to the conclusion it makes sense to install it myself versus paying an installer. I too am in Los Angeles.

This works if you're handy since you'll probably do a better job. Doing things like a nitrogen pressure test, which aren't stated in the manual, is a good practice that many installers will skip unless it's explicitly stated in the manual like in some Mitsubishi units. This practice makes sense for heat pump R410A units which will see upwards of 450 psi on the head when in heat pump mode. But expect to spend $500-$700 on tools if you want to do it right.

Edit: if you want me to comment more on the tools I went with, let me know.
Edit Edit: As promised, I posted my tools breakdown reply on #99 of this thread, but I'm also going to post it below too. If this angers the mods then please remove post #99.



Everyone can decide what you need for your install versus others, but here's the tools that I bought for mine:


Nitrogen Tank w/ Regulator (got on Craigslist)1 $ 100.00
Appion CTEE14 MegaSeal Low-Loss Charging T-Fitting - 1/4'1 $ 49.94
Appion MGAVCR Mega Flow Vacuum Rated Valve Core Removal Tool – 5/16" System Connection1 $ 48.48
CPS VG200: Vacuum Micron Gauge with Digital LCD Display1 $ 146.21
Refrigeration Technologies RT201B Nylog Gasket/Thread Sealant1 $ 10.25
Yellow Jacket 42004 Series 41 Manifold with 3-1/8" Gauge, psi, R-22/404A/410A1 $ 112.29
Yellow Jacket 19173 R-410 5/16" to 1/4" coupler w/ schrader valve.1 $ 14.26
CPS Pro-Set R410A Flare Gauge1 $ 19.81
CPS BLACKMAX BFT850 Ultra-Lightweight R-410A Clutch-Type Ecentric Flaring Tool1 $ 130.03
Reed Tool DEBO Pencil Shape Deburring Tool for Copper1$11.68
RIDGID 32975 Model 103 Close Quarters Tubing Cutter, 1/8-inch to 5/8-inch Tube Cutter , Silver , Small1$12.67
Johnsen's 6915 Vacuum Pump Oil - 12 oz.1 $ 9.79
PITTSBURGH AUTOMOTIVE 3 CFM Two Stage Vacuum Pump1 $ 149.99
PITTSBURGH 3/8 In. Metric Crowfoot Wrench Set, 7 Pc.1 $ 9.99

For mine, it was a total of $825-ish, with it being more like $900 after tax. But I bought multiple things that most people don't need to buy, marked in italics, so you can save a lot of money skipping these. These optional tools represent an additional $372.61 ($400.55 after tax, at least where I live) you can eliminate about 50% from the tools budget.

First and foremost, don't attempt to work with electrical or HVAC unless you're pretty comfortable with DIY projects.

The Nitrogen tank is optional for pressure testing. Some say if you can pull a good vacuum and let it sit for a while that is "good enough" and most company's instructions exclude this from the installation instructions. But it's worth considering because when running R-410A in heat pump mode, you'll get high pressure across your head side of the loop. This makes sense because the high-pressure side = heat. So in my head it made sense you'd want to do a pressurization test and a vacuum down test, since one is pushing apart the fittings (pressure) and the other is sucking them together (vacuum). Since the fittings will all be exposed to both types of pressures it makes sense for me. Follow Dakine or Mitsubishi installation manual instructions for nitrogen pressure testing if you opt to do it. Note that most professional installers WILL SKIP THIS unless it's a unit that requires it (think Mitsubishi) and the installer is one of their "diamond" approved installers or whatever.

Secondly, I bought a flaring tool because I had a 2-head system and cut the tubing to fit the installation and make it more tidy. This is optional and I do not recommend it unless you know what you're doing. It also saves money to skip this. Before cutting, you need to make sure your run or runs have the required length to prevent overcharging the system. If you have a single head unit and end up cutting the tubes to 1/2 the length you may have too much refrigerant in the linesets. Refer to your manual or talk to the company before you decide to do this. And if you decide to do it anyways, yes it must be a HVAC specific flaring tool. Get one with the clutch system to prevent overtightening the flare press and make it foolproof. R-410A runs at too high of pressures to get away with subpar flares. Deciding to just accept the standard length of the copper tubing eliminates the costs associated with the Flaring tool, flaring gauge, deburring tool, and pipe cutting tool.

As for the rest, you do not NEED a digital micron gauge, many just use their normal gauge set's low pressure side gage and watch to see if the needle moves. This will also work. Again I wanted to go with professional duty equipment to get an install I'm 100% confident in. That way if the thing dies in a few years I won't have wonder in the back of my mind whether I screwed up the install. I know 100% my install was perfect. I went with the Yellow Jacket brand gauges, although you could in theory just get the low side gauge, hose, and valve if you're just pulling vacuum and save some money. I'm sure the garden variety chinesium brand gauges are probably perfectly fine for a solo install and will cut the cost in half for them.

The Appion Schrader core removal tool and the t-valve are totally optional too. You'd have to do some youtubing to see how they're used, but here's a great video which shows essentially the same setup I bought: https://www.youtube.com/watch?v=81EeY7SFYJc

But you can skip those tools and just use the Yellow Jacket 5/16" to 1/4" adapter and be just fine without them. Your pressure drawdown will just take a bit longer since you're going through the Schrader valve, and you'll loose a tiny bit of refrigerant before the schrader valve closes. Skipping these tools will save you $130-$140.

For the vacuum pump I went with a harbor freight 3CFM rated 2-stage vacuum pump. I believe it's rated for sub-30 microns of vacuum which is great, and a review on their site showed a guy pulling 13 microns if I recall correctly. To put this into perspective most manufacturers suggest pulling below 500 microns before charging the system. This is slightly overkill but it works for me.

Lastly I already have a torque wrench but you can get them dirt cheap from harbor freight, and I bought some crowfoot wrenches to use with my torque wrench to torque the bolts to the manufacturer's specifications. Will it really matter if you don't do it to spec? I don't know but I'm not finding out.

Then beyond all of this you'll have to run some 220-240v and have a disconnect box by your run. If you're not a confident DIY'er don't go for this, but if you are then just watch plenty of videos of installations, follow the instructions, and you'll be fine.
swechsler
5260 Posts
1161 Reputation
Having a precharged condenser is no big deal; I believe all mini splits are sold that way. In fact, large (residential) ducted A/Cs ship that way as well. But to DIY this, you'll need a vacuum pump to evacuate the air from the line set before you release the refrigerant. I have done a couple of installs of mini splits (not this brand), and it's not that difficult, but you do need to understand exactly what you're doing. Do some reading before you decide to buy this.
flunder
865 Posts
82 Reputation
Taking a quick stab:

Pros-
No duct work is obvious.
On demand which can save heating/cooling bill.
More precise temperature control "zones".

Cons-
The zones play as double edge sword, when moving in or out the heated/air conditioned space takes some getting used to.
The indoor unit hangs on the wall compare to just a register, so the wall is more or less occupied.
Have to run additional electricity to both in door and outdoor units and the tubes from the indoor unit to the outdoor unit.
More filters to clean.

168 Comments

Sign up for a Slickdeals account to remove this ad.

Pro
May 22, 2021
713 Posts
Joined May 2012
May 22, 2021
luddite_cyborg
Pro
May 22, 2021
713 Posts
I need to do some research, maybe someone with the know-how can weigh in:
Comparing the 9000 to 12000 BTU models, the 12000 is quieter and has a variable speed inverter for the heat pump (for $80 more).
I'd prefer the 12000 model but it's oversized for my basement room (~300 sq ft). How bad of an idea is it to install the oversized 12000 BTU model? Can I expect freezing coils, etc. like with a standard window AC?
May 22, 2021
170 Posts
Joined Jun 2011
May 22, 2021
TokyoJimu
May 22, 2021
170 Posts
Quote from luddite_cyborg :
I need to do some research, maybe someone with the know-how can weigh in:
Comparing the 9000 to 12000 BTU models, the 12000 is quieter and has a variable speed inverter for the heat pump (for $80 more).
I'd prefer the 12000 model but it's oversized for my basement room (~300 sq ft). How bad of an idea is it to install the oversized 12000 BTU model? Can I expect freezing coils, etc. like with a standard window AC?
An oversized inverter type isn't usually a problem since it can run at slower speeds. I purposely installed an oversized unit in my living room so I can heat it quickly and I've had no problems in cooling mode.
1
May 22, 2021
9 Posts
Joined Nov 2012
May 22, 2021
MichaelR7517
May 22, 2021
9 Posts
Quote from bargainhunterforever :
As one of the commenters above said you need a vacuum pump to evacuate the lines on these non-DIy units. There are a mess of youtubers that have shown how to install these. As you probably know self install usually violates the warranty but many people have self installed these units successfully. Actually getting the 220V to these units is harder than the evacuation of the lines. My $.02.
so any recommendations on cheap install sources from pro people? cause knowing me i would not even know how to start installing these. i stop at installing portable ACs with window attachments LOL! honestly if anyone knows cheap places or professional people in the LAX area to install one of these would be highly appreciated! or even helpful for others here asking about install or 110v or 230v questions (by the way 110v 9,000 btu and 12,000 btu units for around 700-900 are on amazon....with DYI parts....but no professional install people or companies)
May 22, 2021
113 Posts
Joined Feb 2016
May 22, 2021
Bboy486
May 22, 2021
113 Posts
Is the 18,000 something that can work to cool a garage? Two car and I am aware of air escaping from the door and lack of insulation. But I am in AZ and want to put a gym in my garage.
May 22, 2021
874 Posts
Joined Nov 2017
May 22, 2021
181day
May 22, 2021
874 Posts
Quote from MichaelR7517 :
i want one of these but dont know how to install them! i tried angies list but they get me the central air install people ...in other words more money for installation. anyone know where cheap install places or people are? in the los angeles area? thanks!
Same boat. Local quotes want $4k when the AC is <$1k.
Pro
May 22, 2021
713 Posts
Joined May 2012
May 22, 2021
luddite_cyborg
Pro
May 22, 2021
713 Posts
Quote from TokyoJimu :
An oversized inverter type isn't usually a problem since it can run at slower speeds. I purposely installed an oversized unit in my living room so I can heat it quickly and I've had no problems in cooling mode.
Thank you, this article seems to say the same, over-sizing seems to mainly be a waste regarding cost (as long as the minimum settings overlaps with room requirement): https://www.contractormag.com/hyd...-equipment

For this deal the cost isn't much more, and additional benefits vs the 9000 BTU that I forgot to mention are a lower min outside operating temp (5 vs -13 deg) and longer included line set (16 vs 25 ft).
May 22, 2021
860 Posts
Joined Nov 2009
May 22, 2021
PlanetoftheMapes
May 22, 2021
860 Posts

Our community has rated this post as helpful. If you agree, why not thank PlanetoftheMapes

Quote from 181day :
Same boat. Local quotes want $4k when the AC is <$1k.
I bought a 2-head Senville 22 SER unit last month and came to the conclusion it makes sense to install it myself versus paying an installer. I too am in Los Angeles.

This works if you're handy since you'll probably do a better job. Doing things like a nitrogen pressure test, which aren't stated in the manual, is a good practice that many installers will skip unless it's explicitly stated in the manual like in some Mitsubishi units. This practice makes sense for heat pump R410A units which will see upwards of 450 psi on the head when in heat pump mode. But expect to spend $500-$700 on tools if you want to do it right.

Edit: if you want me to comment more on the tools I went with, let me know.
Edit Edit: As promised, I posted my tools breakdown reply on #99 of this thread, but I'm also going to post it below too. If this angers the mods then please remove post #99.



Everyone can decide what you need for your install versus others, but here's the tools that I bought for mine:


Nitrogen Tank w/ Regulator (got on Craigslist)1 $ 100.00
Appion CTEE14 MegaSeal Low-Loss Charging T-Fitting - 1/4'1 $ 49.94
Appion MGAVCR Mega Flow Vacuum Rated Valve Core Removal Tool – 5/16" System Connection1 $ 48.48

CPS VG200: Vacuum Micron Gauge with Digital LCD Display1 $ 146.21
Refrigeration Technologies RT201B Nylog Gasket/Thread Sealant1 $ 10.25
Yellow Jacket 42004 Series 41 Manifold with 3-1/8" Gauge, psi, R-22/404A/410A1 $ 112.29
Yellow Jacket 19173 R-410 5/16" to 1/4" coupler w/ schrader valve.1 $ 14.26
CPS Pro-Set R410A Flare Gauge1 $ 19.81
CPS BLACKMAX BFT850 Ultra-Lightweight R-410A Clutch-Type Ecentric Flaring Tool1 $ 130.03
Reed Tool DEBO Pencil Shape Deburring Tool for Copper1$11.68
RIDGID 32975 Model 103 Close Quarters Tubing Cutter, 1/8-inch to 5/8-inch Tube Cutter , Silver , Small1$12.67

Johnsen's 6915 Vacuum Pump Oil - 12 oz.1 $ 9.79
PITTSBURGH AUTOMOTIVE 3 CFM Two Stage Vacuum Pump1 $ 149.99
PITTSBURGH 3/8 In. Metric Crowfoot Wrench Set, 7 Pc.1 $ 9.99

For mine, it was a total of $825-ish, with it being more like $900 after tax. But I bought multiple things that most people don't need to buy, marked in italics, so you can save a lot of money skipping these. These optional tools represent an additional $372.61 ($400.55 after tax, at least where I live) you can eliminate about 50% from the tools budget.

First and foremost, don't attempt to work with electrical or HVAC unless you're pretty comfortable with DIY projects.

The Nitrogen tank is optional for pressure testing. Some say if you can pull a good vacuum and let it sit for a while that is "good enough" and most company's instructions exclude this from the installation instructions. But it's worth considering because when running R-410A in heat pump mode, you'll get high pressure across your head side of the loop. This makes sense because the high-pressure side = heat. So in my head it made sense you'd want to do a pressurization test and a vacuum down test, since one is pushing apart the fittings (pressure) and the other is sucking them together (vacuum). Since the fittings will all be exposed to both types of pressures it makes sense for me. Follow Dakine or Mitsubishi installation manual instructions for nitrogen pressure testing if you opt to do it. Note that most professional installers WILL SKIP THIS unless it's a unit that requires it (think Mitsubishi) and the installer is one of their "diamond" approved installers or whatever.

Secondly, I bought a flaring tool because I had a 2-head system and cut the tubing to fit the installation and make it more tidy. This is optional and I do not recommend it unless you know what you're doing. It also saves money to skip this. Before cutting, you need to make sure your run or runs have the required length to prevent overcharging the system. If you have a single head unit and end up cutting the tubes to 1/2 the length you may have too much refrigerant in the linesets. Refer to your manual or talk to the company before you decide to do this. And if you decide to do it anyways, yes it must be a HVAC specific flaring tool. Get one with the clutch system to prevent overtightening the flare press and make it foolproof. R-410A runs at too high of pressures to get away with subpar flares. Deciding to just accept the standard length of the copper tubing eliminates the costs associated with the Flaring tool, flaring gauge, deburring tool, and pipe cutting tool.

As for the rest, you do not NEED a digital micron gauge, many just use their normal gauge set's low pressure side gage and watch to see if the needle moves. This will also work. Again I wanted to go with professional duty equipment to get an install I'm 100% confident in. That way if the thing dies in a few years I won't have wonder in the back of my mind whether I screwed up the install. I know 100% my install was perfect. I went with the Yellow Jacket brand gauges, although you could in theory just get the low side gauge, hose, and valve if you're just pulling vacuum and save some money. I'm sure the garden variety chinesium brand gauges are probably perfectly fine for a solo install and will cut the cost in half for them.

The Appion Schrader core removal tool and the t-valve are totally optional too. You'd have to do some youtubing to see how they're used, but here's a great video which shows essentially the same setup I bought: https://www.youtube.com/watch?v=81EeY7SFYJc

But you can skip those tools and just use the Yellow Jacket 5/16" to 1/4" adapter and be just fine without them. Your pressure drawdown will just take a bit longer since you're going through the Schrader valve, and you'll loose a tiny bit of refrigerant before the schrader valve closes. Skipping these tools will save you $130-$140.

For the vacuum pump I went with a harbor freight 3CFM rated 2-stage vacuum pump. I believe it's rated for sub-30 microns of vacuum which is great, and a review on their site showed a guy pulling 13 microns if I recall correctly. To put this into perspective most manufacturers suggest pulling below 500 microns before charging the system. This is slightly overkill but it works for me.

Lastly I already have a torque wrench but you can get them dirt cheap from harbor freight, and I bought some crowfoot wrenches to use with my torque wrench to torque the bolts to the manufacturer's specifications. Will it really matter if you don't do it to spec? I don't know but I'm not finding out.

Then beyond all of this you'll have to run some 220-240v and have a disconnect box by your run. If you're not a confident DIY'er don't go for this, but if you are then just watch plenty of videos of installations, follow the instructions, and you'll be fine.
Last edited by PlanetoftheMapes May 22, 2021 at 10:05 PM.
1

Sign up for a Slickdeals account to remove this ad.

May 22, 2021
6,792 Posts
Joined Jun 2014
May 22, 2021
ToolDeals
May 22, 2021
6,792 Posts
Quote from JDanger :
Seems like a good deal. Does anyone know how these compare to the MRCOOL DIY units?
Mr Cool comes pre-charged, whereas and according to reviews, you will need some extra tools and supplies to install this one yourself.... like a vacuum pump, freon, electrical requirements, outside mounting brackets, etc. Some installations are reasonably easy, but others can get very expensive and time consuming.

PS: The DuctlessAire units sold on Amazon say 'pre-charged lines."
Last edited by ToolDeals May 22, 2021 at 04:42 PM.
May 22, 2021
133 Posts
Joined Jan 2019
May 22, 2021
HappyScene6682
May 22, 2021
133 Posts
[QUOTE=PlanetoftheMapes;147413035]
Please do! I'm planning on installing a multi zone Mitsubishi unit. It's challenging to determine which tools to spend on and which to save on.
Last edited by HappyScene6682 May 22, 2021 at 05:39 PM.
May 22, 2021
9 Posts
Joined Nov 2012
May 22, 2021
MichaelR7517
May 22, 2021
9 Posts
[quote="HappyScene6682;147413212"]
Quote from PlanetoftheMapes :
Please do! I'm planning on installing a multi zone Mitsubishi unit. It's challenging to determine which tools to spend on and which to save on.
Well the quest
Quote from PlanetoftheMapes :
I bought a 2-head Senville 22 SER unit last month and came to the conclusion it makes sense to install it myself versus paying an installer. I too am in Los Angeles.

This works if you're handy since you'll probably do a better job. Doing things like a nitrogen pressure test, which aren't stated in the manual, is a good practice that many installers will skip unless it's explicitly stated in the manual like in some Mitsubishi units. This practice makes sense for heat pump R410A units which will see upwards of 450 psi on the head when in heat pump mode. But expect to spend $500-$700 on tools if you want to do it right.

Edit: if you want me to comment more on the tools I went with, let me know.
The question remains for me and probably others that want a head start at summer. What to buy, but also where to find an installer for cheap. Im not handy like I used to be....and froggle comes to mind especially with corona virus low income....who to hire for cheap? In LAX or any other areas. I said Angies list before for an app....but the $2000k plus charge comes to mind for a simple mini duct 2 hour install? I could be wrong and maybe its harder than it looks to install so even if the AC is 800 bucks, maybe nowadays its okay for people to charge 1K,2k,7k dollars?!?
2
May 22, 2021
199 Posts
Joined Oct 2018
May 22, 2021
BeautifulStar162
May 22, 2021
199 Posts
I've been waiting awhile for a decent deal on these, seems like they've been few and far between thanks to COVID. Thanks for the info on the inverter. I'm hoping to DIY (except maybe vacuuming the lines), so any info from y'all who've already done it would be a huge help.
May 22, 2021
248 Posts
Joined Dec 2004
May 22, 2021
rcairflyer
May 22, 2021
248 Posts
Quote from Balayya_Fan :
Installer will take care of that right? Do I need to run de humidifier with these?
A dehumidifier is about the opposite of an AC. Similar principle, but the dehumidifier produces heat in addition to removing moisture from the air. To dehumidify in warm months, run your AC more. In cold months, run the dehumidifier.
Last edited by rcairflyer May 22, 2021 at 04:55 PM.
1
Original Poster
May 22, 2021
492 Posts
Joined Dec 2010
May 22, 2021
david3808
Original Poster
May 22, 2021
492 Posts
Quote from BeautifulStar162 :
I've been waiting awhile for a decent deal on these, seems like they've been few and far between thanks to COVID. Thanks for the info on the inverter. I'm hoping to DIY (except maybe vacuuming the lines), so any info from y'all who've already done it would be a huge help.
2 part installation video.

part 1: https://youtu.be/iFBmh29GezU
part 2: https://youtu.be/Uh9bcdpU8gw

part 2 walks you through checking lines for leaks and vacuuming:
https://youtu.be/Uh9bcdpU8gw?t=516

page 29 has the Air Evacuation instructions:
https://ductlessaire.com/wp-conte...lation.pdf
Last edited by david3808 May 22, 2021 at 05:02 PM.
May 23, 2021
2,021 Posts
Joined Jul 2004
May 23, 2021
rcs1
May 23, 2021
2,021 Posts
I'd really love to put one of these in the nook area of my kitchen that gets the hottest -where we eat dinner - but I have no 220 anywhere near it. Not going to spend more on the electrical work then I would on this unit.
1

Sign up for a Slickdeals account to remove this ad.

May 23, 2021
1,444 Posts
Joined May 2006
May 23, 2021
UltraLazer
May 23, 2021
1,444 Posts
These things work but it's not going to heat your place to 80 when it's 0 outside. They are good for maybe a 40 degree temp difference inside and out.
1