Sam's Club has for their Members: Westinghouse 9500-Watt / 12500-Watt Home Backup Gas Powered Portable Generator (WGen9500DF) on sale for $799.98. Shipping is free.
Thanks to Deal Hunter gaamn114 for finding this deal.
Product Information:
9500 Running Watts and 12500 Peak Watts; Remote Start With Included Key Fob, Electric and Recoil Start; Up to 12 Hours of Run Time on a 6.6 Gallon Fuel Tank With Fuel Gauge
Features Two GFCI 120V 5–20R Standard Household Receptacle, One Transfer Switch Ready 120V L14-30R, One RV Ready 120/240V 14–50R, and Two 5V USB Ports; All Outlets Have Rubber Covers for Added Safety
Powered by a Heavy Duty 457cc Westinghouse 4-Stroke OHV Engine Featuring a Long-Lasting Cast Iron Sleeve With Automatic Low Oil Shutdown and Digital Hour Meter
Plug-and-Play: Comes With a Remote Start Key Fob, 12V Battery Charger, Oil, an Oil Funnel, a Tool Kit, and a User's Manual to Get You Started Right Out of the Box (Minimal Assembly Required)
This collaborative space allows users to contribute additional information, tips, and insights to enhance the original deal post. Feel free to share your knowledge and help fellow shoppers make informed decisions.
Sam's Club has for their Members: Westinghouse 9500-Watt / 12500-Watt Home Backup Gas Powered Portable Generator (WGen9500DF) on sale for $799.98. Shipping is free.
Thanks to Deal Hunter gaamn114 for finding this deal.
Product Information:
9500 Running Watts and 12500 Peak Watts; Remote Start With Included Key Fob, Electric and Recoil Start; Up to 12 Hours of Run Time on a 6.6 Gallon Fuel Tank With Fuel Gauge
Features Two GFCI 120V 5–20R Standard Household Receptacle, One Transfer Switch Ready 120V L14-30R, One RV Ready 120/240V 14–50R, and Two 5V USB Ports; All Outlets Have Rubber Covers for Added Safety
Powered by a Heavy Duty 457cc Westinghouse 4-Stroke OHV Engine Featuring a Long-Lasting Cast Iron Sleeve With Automatic Low Oil Shutdown and Digital Hour Meter
Plug-and-Play: Comes With a Remote Start Key Fob, 12V Battery Charger, Oil, an Oil Funnel, a Tool Kit, and a User's Manual to Get You Started Right Out of the Box (Minimal Assembly Required)
Deal History includes data from multiple reputable stores, such as Best Buy, Target, and Walmart. The lowest price among stores for a given day is selected as the "Sale Price".
Sale Price does not include sale prices at Amazon unless a deal was posted by a community member.
Yes, ultimately it might be better to have a few generators at different kW levels depending on application. This unit is really designed for a jobsite or whole home backup, not tailgating or camping. "portable" simply means you can move it around, not that it's going to be fun doing so.
Propane usually takes a kW hit, on the order of 10-15% for both peak and nominal. Also, you will go through propane tanks much faster than you will gas "tanks", but propane should be easier on the engine (cleaner)
Generators are specified by nominal and peak kw. Nominal is what the unit is designed to run for long periods of time. Peak is an instantaneous value caused when something happens all of a sudden but for a very short period of time like a motor or compressor kicking on. Probably not as relevant a number as nominal, as it's much more difficult to plan for peak usages like that.
Ugh the THD debate. Yes these WF non-Pro models have high THD. If I had my druthers, I'd love a low THD unit, but that's not going to happen at these price points. In fact I welcome anyone here to go find a 12.5kW inverter generator. Honda tends to make the largest "home" models but they typically top out around half this kW and cost several times as much.
That said, I believe the THD debate is moot. Would I prefer it? Why not, but I don't think it makes much difference, at least in the scope and scale that one would be using a generator like this. Also, the THD argument is really sourced 30-40 years ago when electronics were much less sophisticated than today. I've really tried finding hard data on this, and all I can find is *theory* about how *long term* use of "high THD" power could potentially cause slight overheating in certain components and perhaps premature failure. There's a LOT of qualifiers in that statement. I have not been able to find even a single semi-scientific study that tried to evaluate if the above assertion was even true. It might be that it is true, but to get to any real level of risk of damage you need to run for 10,000 hours, in which case that might as well as be never for 99.99% of people that own a generator.
Make sure you need this much power before buying. This is overkill unless you are feeding your breaker box. And even at that you better have enough gas on hand as this thing guzzles a 5 gallon gas canister in less than 10 hours.
What I'm hearing from this is that I need to keep like 25 gallons of gas on hand to make sure this works for 2 days? What about propane?? I have wayyyy too many propane tanks. Just keep 6 tanks full and I should be good to go!??
I bought at $849 at the beginning of December and thought I was getting a steal. At $800 I would say this is a can't miss deal.
I was about to say "no, its not dual fuel" just based on OP's listing, but then I checked the Amazon listing, and yes, this can run on propane.
It amazes me how few people think about other fuels, but especially in the case of a backup generator that sees little use, it is tremendously important to NOT use gasoline.
When you ONLY run a generator on propane, you eliminate gunking up the carb with gasoline deposits, and along with that, all of the issues that make it hard to start after it sits for a long time between uses.
If I didn't already have my 12000W dual fuel Duromax, I would definitely buy this.
Yeah, the the THD on this model is >23%. Not so good for certain electronics. I wish it was <5% like the 12000 model. I ended up purchasing the Champion 100520 and am going to convert it to Tri-Fuel which will cost roughly $270.00 all said and done. So, total cost for generator and conversion approximately $$1,206.60 for me.
This thing is 200lb so even with the wheels it would be only minimally portable.
A 4000W generator at 100lb with lesser power will do just fine for emergencies unless you want to host a party as well
I have this unit and it's not bad to move around the yard. It has two handles like aa wheelbarrow. I wouldnt use this a true portable - its too heavy. But to go from garage or shed to house it's fine. It's not nearly as noisy as the Firman that I had before and my LED lights don't flicker. I have run my 4 ton AC with this unit, even with a natural gas conversion I added
Good deal for a big generator, just be aware this isn't for sensitive electronics and its going to drink lots of fuel as it isn't an inverter type that varies RPM based on load.
Yeah, the the THD on this model is >23%. Not so good for certain electronics. I wish it was <5% like the 12000 model. I ended up purchasing the Champion 100520 and am going to convert it to Tri-Fuel which will cost roughly $270.00 all said and done. So, total cost for generator and conversion approximately $$1,206.60 for me.
NG conversion kits for this model are readily available at $129 (no extended search for better deals).
Lots of resellers out there trying to get $169 or more for them, beware.
So $270 seems a liiittle steep...unless maybe including hardware and paid installation from the meter?
Thanks for the tip on the Champion 100520[walmart.com]. Will absolutely never buy a unit like this with crazy high THD.
.
Our community has rated this post as helpful. If you agree, why not thank
Quote
from ZAPWALL
:
This thing is 200lb so even with the wheels it would be only minimally portable.
A 4000W generator at 100lb with lesser power will do just fine for emergencies unless you want to host a party as well
Yes, ultimately it might be better to have a few generators at different kW levels depending on application. This unit is really designed for a jobsite or whole home backup, not tailgating or camping. "portable" simply means you can move it around, not that it's going to be fun doing so.
Quote
from MaroonPocket778
:
Make sure you need this much power before buying. This is overkill unless you are feeding your breaker box. And even at that you better have enough gas on hand as this thing guzzles a 5 gallon gas canister in less than 10 hours.
Quote
from Frugalwallet
:
What I'm hearing from this is that I need to keep like 25 gallons of gas on hand to make sure this works for 2 days? What about propane?? I have wayyyy too many propane tanks. Just keep 6 tanks full and I should be good to go!??
Propane usually takes a kW hit, on the order of 10-15% for both peak and nominal. Also, you will go through propane tanks much faster than you will gas "tanks", but propane should be easier on the engine (cleaner)
Quote
from spittlbm
:
Terrible THD
Quote
from konoplya
:
How do i get peak watts? What's that mean anyway
Generators are specified by nominal and peak kw. Nominal is what the unit is designed to run for long periods of time. Peak is an instantaneous value caused when something happens all of a sudden but for a very short period of time like a motor or compressor kicking on. Probably not as relevant a number as nominal, as it's much more difficult to plan for peak usages like that.
Quote
from BeelzeBuck
:
Yeah, the the THD on this model is >23%. Not so good for certain electronics. I wish it was <5% like the 12000 model. I ended up purchasing the Champion 100520 and am going to convert it to Tri-Fuel which will cost roughly $270.00 all said and done. So, total cost for generator and conversion approximately $$1,206.60 for me.
Quote
from yakky
:
Good deal for a big generator, just be aware this isn't for sensitive electronics and its going to drink lots of fuel as it isn't an inverter type that varies RPM based on load.
Ugh the THD debate. Yes these WF non-Pro models have high THD. If I had my druthers, I'd love a low THD unit, but that's not going to happen at these price points. In fact I welcome anyone here to go find a 12.5kW inverter generator. Honda tends to make the largest "home" models but they typically top out around half this kW and cost several times as much.
That said, I believe the THD debate is moot. Would I prefer it? Why not, but I don't think it makes much difference, at least in the scope and scale that one would be using a generator like this. Also, the THD argument is really sourced 30-40 years ago when electronics were much less sophisticated than today. I've really tried finding hard data on this, and all I can find is *theory* about how *long term* use of "high THD" power could potentially cause slight overheating in certain components and perhaps premature failure. There's a LOT of qualifiers in that statement. I have not been able to find even a single semi-scientific study that tried to evaluate if the above assertion was even true. It might be that it is true, but to get to any real level of risk of damage you need to run for 10,000 hours, in which case that might as well as be never for 99.99% of people that own a generator.
4
1
Like
Helpful
Funny
Not helpful
Sign up for a Slickdeals account to remove this ad.
Yes, ultimately it might be better to have a few generators at different kW levels depending on application. This unit is really designed for a jobsite or whole home backup, not tailgating or camping. "portable" simply means you can move it around, not that it's going to be fun doing so.
Propane usually takes a kW hit, on the order of 10-15% for both peak and nominal. Also, you will go through propane tanks much faster than you will gas "tanks", but propane should be easier on the engine (cleaner)
Generators are specified by nominal and peak kw. Nominal is what the unit is designed to run for long periods of time. Peak is an instantaneous value caused when something happens all of a sudden but for a very short period of time like a motor or compressor kicking on. Probably not as relevant a number as nominal, as it's much more difficult to plan for peak usages like that.
Ugh the THD debate. Yes these WF non-Pro models have high THD. If I had my druthers, I'd love a low THD unit, but that's not going to happen at these price points. In fact I welcome anyone here to go find a 12.5kW inverter generator. Honda tends to make the largest "home" models but they typically top out around half this kW and cost several times as much.
That said, I believe the THD debate is moot. Would I prefer it? Why not, but I don't think it makes much difference, at least in the scope and scale that one would be using a generator like this. Also, the THD argument is really sourced 30-40 years ago when electronics were much less sophisticated than today. I've really tried finding hard data on this, and all I can find is *theory* about how *long term* use of "high THD" power could potentially cause slight overheating in certain components and perhaps premature failure. There's a LOT of qualifiers in that statement. I have not been able to find even a single semi-scientific study that tried to evaluate if the above assertion was even true. It might be that it is true, but to get to any real level of risk of damage you need to run for 10,000 hours, in which case that might as well as be never for 99.99% of people that own a generator.
Thanks so much for the explanations
Like
Helpful
Funny
Not helpful
Join The Conversation
Share your experience with the Slickdeals community
Share information with the community. Please follow our Community Guidelines and be kind!
Top Comments
https://www.amazon.com/dp/B07Q1DLKBG
Propane usually takes a kW hit, on the order of 10-15% for both peak and nominal. Also, you will go through propane tanks much faster than you will gas "tanks", but propane should be easier on the engine (cleaner)
Generators are specified by nominal and peak kw. Nominal is what the unit is designed to run for long periods of time. Peak is an instantaneous value caused when something happens all of a sudden but for a very short period of time like a motor or compressor kicking on. Probably not as relevant a number as nominal, as it's much more difficult to plan for peak usages like that.
Ugh the THD debate. Yes these WF non-Pro models have high THD. If I had my druthers, I'd love a low THD unit, but that's not going to happen at these price points. In fact I welcome anyone here to go find a 12.5kW inverter generator. Honda tends to make the largest "home" models but they typically top out around half this kW and cost several times as much.
That said, I believe the THD debate is moot. Would I prefer it? Why not, but I don't think it makes much difference, at least in the scope and scale that one would be using a generator like this. Also, the THD argument is really sourced 30-40 years ago when electronics were much less sophisticated than today. I've really tried finding hard data on this, and all I can find is *theory* about how *long term* use of "high THD" power could potentially cause slight overheating in certain components and perhaps premature failure. There's a LOT of qualifiers in that statement. I have not been able to find even a single semi-scientific study that tried to evaluate if the above assertion was even true. It might be that it is true, but to get to any real level of risk of damage you need to run for 10,000 hours, in which case that might as well as be never for 99.99% of people that own a generator.
Join The Conversation
Share your experience with the Slickdeals community
Share information with the community. Please follow our Community Guidelines and be kind!
69 Comments
Sign up for a Slickdeals account to remove this ad.
Our community has rated this post as helpful. If you agree, why not thank
It amazes me how few people think about other fuels, but especially in the case of a backup generator that sees little use, it is tremendously important to NOT use gasoline.
When you ONLY run a generator on propane, you eliminate gunking up the carb with gasoline deposits, and along with that, all of the issues that make it hard to start after it sits for a long time between uses.
If I didn't already have my 12000W dual fuel Duromax, I would definitely buy this.
Sign up for a Slickdeals account to remove this ad.
https://www.amazon.com/dp/B07Q1DLKBG
This one looks a little slicker, duel fuel & remote start
A 4000W generator at 100lb with lesser power will do just fine for emergencies unless you want to host a party as well
Lots of resellers out there trying to get $169 or more for them, beware.
So $270 seems a liiittle steep...unless maybe including hardware and paid installation from the meter?
Thanks for the tip on the Champion 100520 [walmart.com]. Will absolutely never buy a unit like this with crazy high THD.
.
A 4000W generator at 100lb with lesser power will do just fine for emergencies unless you want to host a party as well
Our community has rated this post as helpful. If you agree, why not thank
A 4000W generator at 100lb with lesser power will do just fine for emergencies unless you want to host a party as well
That said, I believe the THD debate is moot. Would I prefer it? Why not, but I don't think it makes much difference, at least in the scope and scale that one would be using a generator like this. Also, the THD argument is really sourced 30-40 years ago when electronics were much less sophisticated than today. I've really tried finding hard data on this, and all I can find is *theory* about how *long term* use of "high THD" power could potentially cause slight overheating in certain components and perhaps premature failure. There's a LOT of qualifiers in that statement. I have not been able to find even a single semi-scientific study that tried to evaluate if the above assertion was even true. It might be that it is true, but to get to any real level of risk of damage you need to run for 10,000 hours, in which case that might as well as be never for 99.99% of people that own a generator.
Sign up for a Slickdeals account to remove this ad.
Propane usually takes a kW hit, on the order of 10-15% for both peak and nominal. Also, you will go through propane tanks much faster than you will gas "tanks", but propane should be easier on the engine (cleaner)
Generators are specified by nominal and peak kw. Nominal is what the unit is designed to run for long periods of time. Peak is an instantaneous value caused when something happens all of a sudden but for a very short period of time like a motor or compressor kicking on. Probably not as relevant a number as nominal, as it's much more difficult to plan for peak usages like that.
Ugh the THD debate. Yes these WF non-Pro models have high THD. If I had my druthers, I'd love a low THD unit, but that's not going to happen at these price points. In fact I welcome anyone here to go find a 12.5kW inverter generator. Honda tends to make the largest "home" models but they typically top out around half this kW and cost several times as much.
That said, I believe the THD debate is moot. Would I prefer it? Why not, but I don't think it makes much difference, at least in the scope and scale that one would be using a generator like this. Also, the THD argument is really sourced 30-40 years ago when electronics were much less sophisticated than today. I've really tried finding hard data on this, and all I can find is *theory* about how *long term* use of "high THD" power could potentially cause slight overheating in certain components and perhaps premature failure. There's a LOT of qualifiers in that statement. I have not been able to find even a single semi-scientific study that tried to evaluate if the above assertion was even true. It might be that it is true, but to get to any real level of risk of damage you need to run for 10,000 hours, in which case that might as well as be never for 99.99% of people that own a generator.
Join The Conversation
Share your experience with the Slickdeals community
Share information with the community. Please follow our Community Guidelines and be kind!