30A dryer or water heater circuits will usually be 10 AWG, and 50A stove or EV charging stations will be 6 AWG.
8/3 is rated for 40 amps which is in no man's land - there aren't any 40A standard receptacles. Typically in a residential applications you would see 8 AWG circuits for like a 4 ton AC compressor, a cooktop or in-wall oven, or a hardwired EV charging station. Of those, only the in-wall oven actually needs the 3rd (neutral) wire so most would use 8/2. Probably why this is on sale.
Sign up for a Slickdeals account to remove this ad.
The conventional wisdom is to use copper wiring, an industrial grade socket (eg Hubbell or similar), and check the wiring of the socket yearly and re-torque to make sure the wire isn't backing out.