75-Feet Southwire 8/3 Romex SIMpull Stranded Indoor CU NM-B W/G Wire

+ Free Shipping

$152

$200

24% off
Lowe's
84 Comments 45,533 Views
Get Deal at Lowe's
Good Deal
Save
Share
Deal Details
Lowe's has 75-Feet Southwire 8/3 Romex SIMpull Stranded Indoor CU NM-B W/G Wire (63949207) for $152.28. Shipping is free.

Thanks to Community Member mkzmkz for posting this deal.

Features:
  • Southwire's Romex SIMpull type NM-B may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C
  • NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads
  • NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations
  • Voltage rating for NM-B cable is 600 volts
  • Copper conductors are annealed (soft) copper
  • Southwire's SIMpull designed for easier pulling, resulting in easier installation
  • UL listed

Editor's Notes

Written by StrawMan86 | Staff
  • 4.6 out of 5 stars rating at Lowe's based on 100+ customer reviews.
  • Refer to the original post & forum comments for additional details & discussion.

Original Post

Written by mkzmkz
Product Info
Community Notes
About the Poster
Deal Details
Product Info
Community Notes
About the Poster
Lowe's has 75-Feet Southwire 8/3 Romex SIMpull Stranded Indoor CU NM-B W/G Wire (63949207) for $152.28. Shipping is free.

Thanks to Community Member mkzmkz for posting this deal.

Features:
  • Southwire's Romex SIMpull type NM-B may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C
  • NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads
  • NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations
  • Voltage rating for NM-B cable is 600 volts
  • Copper conductors are annealed (soft) copper
  • Southwire's SIMpull designed for easier pulling, resulting in easier installation
  • UL listed

Editor's Notes

Written by StrawMan86 | Staff
  • 4.6 out of 5 stars rating at Lowe's based on 100+ customer reviews.
  • Refer to the original post & forum comments for additional details & discussion.

Original Post

Written by mkzmkz

Community Voting

Deal Score
+26
Good Deal
Get Deal at Lowe's

Price Intelligence

Model: Southwire 75-ft 8 / 3 Romex SIMpull Stranded Indoor Non-Metallic Wire (By-the-roll) | 63949207

Deal History 

Sale Price
Slickdeal
  • $NaN
  • Today

Current Prices

Sort: Lowest to Highest | Last Updated 7/14/2025, 08:51 AM
Sold By Sale Price
Lowe's$159.98

Leave a Comment

Unregistered (You)

Top Comments

mkzmkz
75 Posts
46 Reputation
Most typical use is electrical stove/range. For EV charges, you'd want to go with 6 guage if you can (and your panel allows it).
NeatOstrich900
69 Posts
14 Reputation
Highly recommended to over size wiring for EV charging.
Masejoer
2853 Posts
596 Reputation
And if not hard-wired, a quality 14-50R if going for 40A continuous - not the $10 things sold at the big box stores. $50+ Hubbell HBL9450A or equivalent for reliability.

83 Comments

Sign up for a Slickdeals account to remove this ad.

Feb 22, 2025
1,303 Posts
Joined Oct 2009
Feb 22, 2025
ducksoup18
Feb 22, 2025
1,303 Posts
Quote from Asok28 :
Shows up as $75 a roll for me. That seems pretty slick.
Which store?
Feb 22, 2025
399 Posts
Joined Jul 2013
Feb 22, 2025
Golfer2000
Feb 22, 2025
399 Posts
Quote from JasonStern :
Obligatory not a licensed electrician, consult a professional, check local building codes, etc. warning.
This is too thin for level 2 charging. My Tesla charger runs 6/3 and even then I cap charging at 32A, even though everything is rated at 50A. When in doubt, go heavier and under utilize it. Bad things are less likely to happen going that path rather than the opposite. And in most cases, the cost differences aren't that significant. Refer to:
https://www.tesla.com/support/cha...installing
That said, this 8/3 would be great for most dryers, convectional ovens, and small campers - devices rated ideally below 30A peak.
Most wires, including this one, is rated to 600V - which you aren't going to get off a typical breaker box. Continuous amperage is what you need to worry about and adjust your wiring size accordingly. Again, when in doubt, go one gauge higher.
Just because the tesla charger can max out this wire doesn't mean you have to run the charger that hot. Use an appropriate sized breaker, properly set your tesla charger and this wire is fine.
Feb 22, 2025
2,411 Posts
Joined Jul 2017
Feb 22, 2025
fintlewoodlewix
Feb 22, 2025
2,411 Posts
We have 10 gauge THHN running in metal conduit to two hardwired chargers in the garage. Seems to work just fine for the past 10 years or so. There was a lot of cursing and grunting as it was pulled.
Feb 22, 2025
77 Posts
Joined Nov 2013
Feb 22, 2025
sqlman56
Feb 22, 2025
77 Posts
Quote from scraejtp :
All kinds of things. An EVSE (electric vehicle charger) is a typical use. 40A circuit, good for 32A continuous. Typically do not need 8/3 though, 8/2 (no neutral) would be sufficient.
Modern NEC code requires 3 wire even for appliances and especially for an EV charger that may end up outside
Feb 22, 2025
95 Posts
Joined Dec 2005
Feb 22, 2025
mrmom
Feb 22, 2025
95 Posts
menards has it for $130 after rebate

https://www.menards.com/main/elec...c-6441.htm
Feb 22, 2025
526 Posts
Joined Jan 2014
Feb 22, 2025
SLICKDEALIOZ
Feb 22, 2025
526 Posts
1
Feb 22, 2025
3,060 Posts
Joined Aug 2009
Feb 22, 2025
Teaser38
Feb 22, 2025
3,060 Posts
Quote from sqlman56 :
Modern NEC code requires 3 wire even for appliances and especially for an EV charger that may end up outside
3 wire, yes. 3 conductor, no. Modern Romex only states the number of conductor but includes a properly sized ground wire. So 8/2 has 2 conducting wires and a ground wire.

Sign up for a Slickdeals account to remove this ad.

Pro
Feb 22, 2025
1,473 Posts
Joined Jun 2004
Feb 22, 2025
kingkong00
Pro
Feb 22, 2025
1,473 Posts
Why am I seeing $75 price? Anyone else?
Feb 22, 2025
3,060 Posts
Joined Aug 2009
Feb 22, 2025
Teaser38
Feb 22, 2025
3,060 Posts
My 2¢... For EVs, most people's will do fine just charging off a 120V wall socket. 99% of people will do fine with 12AWG and 240V. For 99.95% of people 32A is fine, but if you are installing 8AWG Romex the NEC gives you a pretty bad deal on the cable's ampacity. Run 6/2 (or at least run 8AWG in 3/4" conduit or super cheap 6-6-6 AL SEU) or better instead.
Feb 22, 2025
623 Posts
Joined May 2011
Feb 22, 2025
mprincebuyer
Feb 22, 2025
623 Posts
Would this work for basement finishing - switches, outlets and lighting - to be used in conduit?

Also shows this as "normal" price. SD says this was around $60 earlier this past year?
Last edited by mprincebuyer February 22, 2025 at 12:30 PM.
Feb 22, 2025
848 Posts
Joined Jun 2018
Feb 22, 2025
JasonStern
Feb 22, 2025
848 Posts
Quote from Golfer2000 :
Just because the tesla charger can max out this wire doesn't mean you have to run the charger that hot. Use an appropriate sized breaker, properly set your tesla charger and this wire is fine.
Obligatory not a licensed electrician, contact one before even looking at a wire disclaimer...

Could this be used to charge EVs? Sure. So can 120V extension cords at level 1 rates.
But you would be completely negating the point of Tesla's level 2 charger. At 8/3, you're peak 30 amps, 24 continuous. That's about 20 miles an hour charge time. Meanwhile, the breakers, insulation, etc. are all around the same cost if you want to run 50A versus 30A. Only difference is the wire.
And you're putting this much effort into installing an EV charger, the cost of going with a higher gauge wire is totally justifiable. Having an EV charger in your house does add value to the home. Not what you put into it, but it does add some.
Plus, this is indoor rated cord. So, you would be having an in garage charger. And most garages aren't 75 feet away from the breaker box. I guess you could try to sell the leftover wire..
Again, this is perfect for a 30A dryer, convectional oven, garaged camper, etc. But for a modern EV, you should consider going with at least a 50A setup - meaning 6/3. And consider under-driving the continuous load to add an additional level of safety.
Feb 22, 2025
848 Posts
Joined Jun 2018
Feb 22, 2025
JasonStern
Feb 22, 2025
848 Posts
Quote from Teaser38 :
My 2¢... For EVs, most people's will do fine just charging off a 120V wall socket. 99% of people will do fine with 12AWG and 240V. For 99.95% of people 32A is fine, but if you are installing 8AWG Romex the NEC gives you a pretty bad deal on the cable's ampacity. Run 6/2 (or at least run 8AWG in 3/4" conduit or super cheap 6-6-6 AL SEU) or better instead.
Blah blah blah, consult a licensed electrician disclaimer.
Somewhat disagree. Installing a higher amperage charger has drastically reduced charging times, making owning an EV significantly more practical. While Tesla's charge points are decently abundant, the cost associated with them doesn't provide the true savings capable of owning an EV. Plus since my car isn't garaged, I always worry about the level 1 charger being stolen if I were to charge overnight.
Totally agree with your cable suggestion, though. Although 6/3 is really needed for Tesla's charger. Other chargers I am not familiar with. For maximum charge, run 4/3 with 60A breakers and proper conduit. But that tends to be much harder to source. And more amperage means more focus on proper heat dissipation.
Feb 22, 2025
848 Posts
Joined Jun 2018
Feb 22, 2025
JasonStern
Feb 22, 2025
848 Posts
Quote from mprincebuyer :
Would this work for basement finishing - switches, outlets and lighting - to be used in conduit?

Also shows this as "normal" price. SD says this was around $60 earlier this past year?
Blah blah blah, consult a licensed electrician disclaimer.
Perfect cable for a 24A continuous, 30A peak basement. If you plan on exceeding that, you'll need to run a second line or go with a higher gauge wire.
Feb 22, 2025
623 Posts
Joined May 2011
Feb 22, 2025
mprincebuyer
Feb 22, 2025
623 Posts
Quote from JasonStern :
Blah blah blah, consult a licensed electrician disclaimer.
Perfect cable for a 24A continuous, 30A peak basement. If you plan on exceeding that, you'll need to run a second line or go with a higher gauge wire.
lol everyone takes this as personalized advice. that's why i come to SD for my needs.

Sign up for a Slickdeals account to remove this ad.

Feb 22, 2025
848 Posts
Joined Jun 2018
Feb 22, 2025
JasonStern
Feb 22, 2025
848 Posts
Quote from mprincebuyer :
lol everyone takes this as personalized advice. that's why i come to SD for my needs.
Just trying to help someone not burn their house down.