This collaborative space allows users to contribute additional information, tips, and insights to enhance the original deal post. Feel free to share your knowledge and help fellow shoppers make informed decisions.
Got this last time when it was 136. Install was an adventure but doable with some Ai help. I don't use their app, but display my stats on a little e-ink panel, snd download values into a database. Works really well! I learned a lot about the various loads.
Our community has rated this post as helpful. If you agree, why not thank
Not bad for the price. ETL certified, Home Assistant integration via MQTT.
Before buying, I suggest to count the number of breakers in your electric panel, and make sure you've got enough channels and coils to cover. Standard 200 Amp panel may have somewhat between 20 and 40 breakers. Some double-pole breakers (with symmetric 220v loads/no neutral) may require only one channel/coil with proper configuration.
Personally, I've been using 32-channel Brultech, and still have a few, that I decided to opt out on monitoring.
Our community has rated this post as helpful. If you agree, why not thank
Got this last time when it was 136. Install was an adventure but doable with some Ai help. I don't use their app, but display my stats on a little e-ink panel, snd download values into a database. Works really well! I learned a lot about the various loads.
Hi, do you own the residential model? how many channels do you monitor? Do you use Home Assistant? And what communications method are you using? Thanks!
Quote
from VladStar
:
Not bad for the price. ETL certified, Home Assistant integration via MQTT.
Before buying, I suggest to count the number of breakers in your electric panel, and make sure you've got enough channels and coils to cover. Standard 200 Amp panel may have somewhat between 20 and 40 breakers. Some double-pole breakers (with symmetric 220v loads/no neutral) may require only one channel/coil with proper configuration.
Personally, I've been using 32-channel Brultech, and still have a few, that I decided to opt out on monitoring.
They sent me one of these to test back in 2025 and I've been happy with it. I use it in an offline network with Home Assistant and it works great for that. My only complaint, which someone else mentioned, is the number of channels is IMO low for modern homes. I had to pick and choose which circuits I really wanted to monitor because I didn't have enough to cover all of them. I ended up going for the heavy hitters.
Hi, do you own the residential model? how many channels do you monitor? Do you use Home Assistant? And what communications method are you using? Thanks!
[IMG]https://static.slickdealscdn.com/images/smilies/biggrin.gif[/IMG]
I have 32-channel GEM (Green Eye Monitor) with WiFi module, have been using custom integration from HACS
(https://github.com/jkeljo/hacs-greeneye-monitor), using Bin32 NET format.
Also have a bunch of temperature probes connected to it (furnace main/return ducts, ac line, cold/hot water, outdoor), as it sits in a basement right next to them 😃
It's interface is a bit obsolete, but works well. Recently, after 8 years of service, it started acting up, Ben and Paul from Brultech helped me to troubleshoot the problem, narrowed down to the bad IC7 voltage regulator and sent a replacement part, which I re-soldered. Respect and many thanks to them for such a great support!
Last edited by VladStar November 26, 2026 at 12:55 AM.
Not bad for the price. ETL certified, Home Assistant integration via MQTT.
Before buying, I suggest to count the number of breakers in your electric panel, and make sure you've got enough channels and coils to cover. Standard 200 Amp panel may have somewhat between 20 and 40 breakers. Some double-pole breakers (with symmetric 220v loads/no neutral) may require only one channel/coil with proper configuration.
Personally, I've been using 32-channel Brultech, and still have a few, that I decided to opt out on monitoring.
So this is measuring per breaker vs per outlet or device?
Like
Helpful
Funny
Not helpful
Sign up for a Slickdeals account to remove this ad.
i see $152 here, open source friendly (edit: only local control friendly, it appears?)
vs $160 meross (36% bf sale)
where are you seeing cheaper? meross is not open source at all - we should be willing to pay more for FOSS, where we (actually) own it. but again, it actually looks cheaper?
i see $152 here, open source friendly (edit: only local control friendly, it appears?)
vs $160 meross (36% bf sale)
where are you seeing cheaper? meross is not open source at all - we should be willing to pay more for FOSS, where we (actually) own it. but again, it actually looks cheaper?
Or, just buy the one that is not only cheaper but supports it without having to flash the firmware. Weird that you are hung up on my answer to someone asking a question.
i see $152 here, open source friendly (edit: only local control friendly, it appears?)vs $160 meross (36% bf sale)where are you seeing cheaper? meross is not open source at all - we should be willing to pay more for FOSS, where we (actually) own it. but again, it actually looks cheaper?I use lanternpowermonitor - fully FOSS, rpi brains. There is also FOSS esp firmware replacement for the Emporia Vue 2 & Vue 3: https://emporia-vue-local.github..../flashing/
Meross and Refoss are the same company, EM16P is the same hardware sold under both labels. They were saying that $152 here is cheaper than the $200+ Emporia Vue, in answer to my question about comparisons.
Like
Helpful
Funny
Not helpful
Sign up for a Slickdeals account to remove this ad.
This seems cool and I have HA set up at home, but it's it really that valuable? Maybe shows you how much your AC uses compared to electric dryer, anything else useful?
Like
Helpful
Funny
Not helpful
Join The Conversation
Share your experience with the Slickdeals community
Share information with the community. Please follow our Community Guidelines and be kind!
Top Comments
Join The Conversation
Share your experience with the Slickdeals community
Share information with the community. Please follow our Community Guidelines and be kind!
17 Comments
Sign up for a Slickdeals account to remove this ad.
Our community has rated this post as helpful. If you agree, why not thank
Before buying, I suggest to count the number of breakers in your electric panel, and make sure you've got enough channels and coils to cover. Standard 200 Amp panel may have somewhat between 20 and 40 breakers. Some double-pole breakers (with symmetric 220v loads/no neutral) may require only one channel/coil with proper configuration.
Personally, I've been using 32-channel Brultech, and still have a few, that I decided to opt out on monitoring.
Our community has rated this post as helpful. If you agree, why not thank
Before buying, I suggest to count the number of breakers in your electric panel, and make sure you've got enough channels and coils to cover. Standard 200 Amp panel may have somewhat between 20 and 40 breakers. Some double-pole breakers (with symmetric 220v loads/no neutral) may require only one channel/coil with proper configuration.
Personally, I've been using 32-channel Brultech, and still have a few, that I decided to opt out on monitoring.
[IMG]https://static.slickdealscdn.com/images/smilies/biggrin.gif[/IMG]
(https://github.com/jkeljo/hacs-greeneye-monitor), using Bin32 NET format.
Also have a bunch of temperature probes connected to it (furnace main/return ducts, ac line, cold/hot water, outdoor), as it sits in a basement right next to them 😃
It's interface is a bit obsolete, but works well. Recently, after 8 years of service, it started acting up, Ben and Paul from Brultech helped me to troubleshoot the problem, narrowed down to the bad IC7 voltage regulator and sent a replacement part, which I re-soldered. Respect and many thanks to them for such a great support!
Before buying, I suggest to count the number of breakers in your electric panel, and make sure you've got enough channels and coils to cover. Standard 200 Amp panel may have somewhat between 20 and 40 breakers. Some double-pole breakers (with symmetric 220v loads/no neutral) may require only one channel/coil with proper configuration.
Personally, I've been using 32-channel Brultech, and still have a few, that I decided to opt out on monitoring.
Sign up for a Slickdeals account to remove this ad.
vs $160 meross (36% bf sale)
where are you seeing cheaper? meross is not open source at all - we should be willing to pay more for FOSS, where we (actually) own it. but again, it actually looks cheaper?
I use lanternpowermonitor - fully FOSS, rpi brains. There is also FOSS esp firmware replacement for the Emporia Vue 2 & Vue 3: https://emporia-vue-local.github...
Yeah. Meross is cheaper, and better if you value integration and ecosystem. Vue is good if you only want to use the data in their app.
vs $160 meross (36% bf sale)
where are you seeing cheaper? meross is not open source at all - we should be willing to pay more for FOSS, where we (actually) own it. but again, it actually looks cheaper?
I use lanternpowermonitor - fully FOSS, rpi brains. There is also FOSS esp firmware replacement for the Emporia Vue 2 & Vue 3: https://emporia-vue-local.github...
Sign up for a Slickdeals account to remove this ad.
Join The Conversation
Share your experience with the Slickdeals community
Share information with the community. Please follow our Community Guidelines and be kind!