Slickdeals is community-supported.  We may get paid by brands for deals, including promoted items.
Missed This Deal? Get alerts when similar deals are posted.
expired
Discombobulated | Staff 55.8K Views
Feb 24, 2021 9:02 AM

1000' Monoprice Cat6 Solid 550MHz 23AWG Pure Bare Copper Wire Ethernet Cable

$90

$103

12% off
+ Free Shippingat Monoprice
Visit Monoprice
Good Deal?
164Comments
Save
Share
Deal Details
Monoprice has 1000' Monoprice Cat6 Solid 550MHz Riser Rated 23AWG Pure Bare Copper Wire Ethernet Cable (Various Colors) for $89.99. Shipping is free.

Thanks to Deal Editor Discombobulated for finding this deal.

Available colors:Features:
  • Unshielded Twisted Pair (UTP) Category 6 Ethernet cable
  • 23AWG solid, pure bare copper conductors
  • CMR (Riser) fire safety rating
  • 550MHz bandwidth
  • 1000 foot roll

Editor's Notes

Written by powerfuldoppler | Staff
  • About this product:
    • Rating of 4.8 from over 260 Monoprice customer reviews.
  • About this store:
    • Details of Monoprice's return policy can be found here.
No longer available:

Original Post

Community Notes
About the Poster
Deal Details
Community Notes
About the Poster
Monoprice has 1000' Monoprice Cat6 Solid 550MHz Riser Rated 23AWG Pure Bare Copper Wire Ethernet Cable (Various Colors) for $89.99. Shipping is free.

Thanks to Deal Editor Discombobulated for finding this deal.

Available colors:Features:
  • Unshielded Twisted Pair (UTP) Category 6 Ethernet cable
  • 23AWG solid, pure bare copper conductors
  • CMR (Riser) fire safety rating
  • 550MHz bandwidth
  • 1000 foot roll

Editor's Notes

Written by powerfuldoppler | Staff
  • About this product:
    • Rating of 4.8 from over 260 Monoprice customer reviews.
  • About this store:
    • Details of Monoprice's return policy can be found here.
No longer available:

Original Post

Community Voting

Deal Score
+111
Good Deal

Top Comments

Join The Conversation

Share your experience with the Slickdeals community

Share information with the community. Please follow our Community Guidelines and be kind!

164 Comments

Sign up for a Slickdeals account to remove this ad.

Feb 25, 2021 2:17 AM
4.4K Comments
Joined Jul 2005
geekwithoutacauseFeb 25, 2021 2:17 AM
4.4K Comments
Quote from lxc1227 View quoted comment :
Highly possible. I put away the box in my attic. It is solid wire and it does look copper, I can't be sure 100% pure cooper.

The fun was to do crossed wires and I made my shares of mistakes. Definitely a cable tester is a must.

edit: for wall jacks, I recommend the keystone punch-down jacks.
I agree. The punch downs work best for me too.
I've tried all the other ones and keep coming back to punch down.
I use a cheapy chinese tester that shows the wires are wired correctly. Doesn't show how much bandwidth but I run some speedtests and it usually works great.
Feb 25, 2021 2:25 AM
2K Comments
Joined Dec 2005
cj0rFeb 25, 2021 2:25 AM
2K Comments
Quote from danny951 View quoted comment :
I bought and installed 1000' of monoprice cat6 cable in my new home during framing. 6 months later I got a recall notice that the jackets on the cable were not fire rated even though they were marked UL/CL2 or whatever. They are telling me they will pay to have the cable replaced in the walls and have sent new cable, but the contractor they have offered said they can't do the job because the cable was stapled to the studs and they can't do drywall work. So monoprice told me to find someone else on my own to replace the cable and rip up my walls, and rip up a stone fireplace for one of the runs. It has been a nightmare.

Still not sure I will ever buy monoprice cable again for in wall application.
So I get you're upset about the situation, but you're giving them crap for trying to make it right? I can't think of many companies that would even offer this level of service to make things proper again.

You gotta give them some credit since most modern companies would leave you high and dry and make you fight to make things right. They'd force your to pursue legal paths which are an absolute nightmare and take a long time to resolve.
Feb 25, 2021 2:26 AM
1K Comments
Joined Nov 2016
edge929Feb 25, 2021 2:26 AM
1K Comments
Quote from geekwithoutacause View quoted comment :
copper clad
Just to be clear, product page specifically says it is not CCA "Monoprice Ethernet cables are made of 100% pure bare copper wire, as opposed to copper clad aluminum (CCA) wire". I still have some laying around from my house build, terminated 100+ ends and as far as I can tell it's copper all the way through. I hate stranded and CCA cable and only use those for short runs, not in-wall.

Edit - Added clarification (thanks cj0r)
Last edited by edge929 February 24, 2021 at 06:47 PM.
Feb 25, 2021 2:29 AM
165 Comments
Joined Mar 2012
cattywhFeb 25, 2021 2:29 AM
165 Comments
I only need 250ft for my new addition.
2
Feb 25, 2021 2:40 AM
1.2K Comments
Joined Oct 2015
BobertbosunFeb 25, 2021 2:40 AM
1.2K Comments
Quote from danny951 View quoted comment :
I bought and installed 1000' of monoprice cat6 cable in my new home during framing. 6 months later I got a recall notice that the jackets on the cable were not fire rated even though they were marked UL/CL2 or whatever. They are telling me they will pay to have the cable replaced in the walls and have sent new cable, but the contractor they have offered said they can't do the job because the cable was stapled to the studs and they can't do drywall work. So monoprice told me to find someone else on my own to replace the cable and rip up my walls, and rip up a stone fireplace for one of the runs. It has been a nightmare.

Still not sure I will ever buy monoprice cable again for in wall application.
When was this? Is there a way to tell if a box has issues? I have a 1000' box I haven't opened yet
Feb 25, 2021 2:41 AM
550 Comments
Joined Sep 2008
dieselfrogFeb 25, 2021 2:41 AM
550 Comments
This is good stuff. I installed over 3k foot of this stuff when building my house a few years ago. Use it for lots of functions: data (obviously), security cameras, POE for mounted smart home tablets, phone, Video and even USB so I can control my media server in my basement from the living room. CAT6 is useful for many things. Run this to every room in your house (several drops each).
Feb 25, 2021 2:42 AM
2.3K Comments
Joined Nov 2016
Tbl5143Feb 25, 2021 2:42 AM
2.3K Comments
Quote from cj0r View quoted comment :
So I get you're upset about the situation, but you're giving them crap for trying to make it right? I can't think of many companies that would even offer this level of service to make things proper again.

You gotta give them some credit since most modern companies would leave you high and dry and make you fight to make things right. They'd force your to pursue legal paths which are an absolute nightmare and take a long time to resolve.
They probably figure it's cheaper to offer it upfront and only a fraction actually taking them up on it, than pay that plus a whole lot more for a class action suit? Just a guess, I'm no legal expert...

That being said, I've used a similar cable from them in my home as well, but I guess 10 years ago I did pay a whole lot less (yes, for pure copper). $90 sounds like a lot, but I guess with inflation it's probably pretty good deal now. I'm just glad I didn't get such a recall notice...

Sign up for a Slickdeals account to remove this ad.

Feb 25, 2021 2:44 AM
2K Comments
Joined Dec 2005
cj0rFeb 25, 2021 2:44 AM
2K Comments
Quote from edge929 View quoted comment :
Product page specifically says it is not CCA "Monoprice Ethernet cables are made of 100% pure bare copper wire, as opposed to copper clad aluminum (CCA) wire". I still have some laying around from my house build, terminated 100+ ends and as far as I can tell it's copper all the way through. I hate stranded and CCA cable and only use those for short runs, not in-wall.
You read his comment out of context; he was responding to another poster claiming to have gotten similar cable for $50>
Feb 25, 2021 2:51 AM
675 Comments
Joined Dec 2011
br1ckhouseFeb 25, 2021 2:51 AM
675 Comments
If I want this to be installed in an office but needs wire runs across the ceiling, CMR isn't enough right? I believe I need plenum but correct me if I am misunderstanding this.
Last edited by br1ckhouse February 24, 2021 at 06:54 PM.
Feb 25, 2021 3:15 AM
90 Comments
Joined Nov 2019
PballinFeb 25, 2021 3:15 AM
90 Comments
Quote from kevbot8 View quoted comment :
When was this? Is there a way to tell if a box has issues? I have a 1000' box I haven't opened yet
Check this out buddy...

UL JACKET MARKINGS FOR AFFECTED CABLES:

(UL) E467139 23AWGX4P CMR CAT6 UTP RoHS Compliance XXXXFT.
(UL) E333346 23AWGX4P CMR CAT6 UTP RoHS Compliance XXXXFT.
(UL) E339722 23AWGX4P CMR CAT6 UTP RoHS Compliance XXXXFT.
If the cables do not bear one of the above cable jacket markings, they are not part of the voluntary recall. Likewise, if the cables, as installed, are less than 50 ft. in length. enter the building from the outside and terminate in an enclosure or listed primary protector, and are not installed inside risers, ducts, plenums and other space used for environmental air, removal is not required.

https://mpcmrrecall.com
Last edited by Pballin February 24, 2021 at 07:20 PM.
Feb 25, 2021 3:23 AM
1.2K Comments
Joined Oct 2015
BobertbosunFeb 25, 2021 3:23 AM
1.2K Comments
Quote from Pballin View quoted comment :
Check this out buddy...

UL JACKET MARKINGS FOR AFFECTED CABLES:

(UL) E467139 23AWGX4P CMR CAT6 UTP RoHS Compliance XXXXFT.
(UL) E333346 23AWGX4P CMR CAT6 UTP RoHS Compliance XXXXFT.
(UL) E339722 23AWGX4P CMR CAT6 UTP RoHS Compliance XXXXFT.
If the cables do not bear one of the above cable jacket markings, they are not part of the voluntary recall. Likewise, if the cables, as installed, are less than 50 ft. in length. enter the building from the outside and terminate in an enclosure or listed primary protector, and are not installed inside risers, ducts, plenums and other space used for environmental air, removal is not required.

https://mpcmrrecall.com
I'm clear, thanks and repped!
Feb 25, 2021 3:24 AM
2K Comments
Joined May 2012
Chemosh013Feb 25, 2021 3:24 AM
2K Comments
Quote from 1200mk View quoted comment :
what kind of rj connectors did you choose? I had some that came with the insert and those were a pain to use.
I used these for my monoprice cable. Be warned they are good quality but the little pieces of copper that pierce the cable can fall out in transit. In my box of 50, maybe 6 or 7 were missing one of the connectors. Still recommend them as they fit monoprice larger gauge cable and if you do it right, they work flawlessly. Takes a little getting used to to feed them through but I got a solid connector everytime.

https://www.amazon.com/Platinum-C...07QD73YXJ/
Last edited by Chemosh013 February 24, 2021 at 07:33 PM.
Feb 25, 2021 3:38 AM
614 Comments
Joined Sep 2011
Ruslan09Feb 25, 2021 3:38 AM
614 Comments
Quote from danny951 View quoted comment :
I bought and installed 1000' of monoprice cat6 cable in my new home during framing. 6 months later I got a recall notice that the jackets on the cable were not fire rated even though they were marked UL/CL2 or whatever. They are telling me they will pay to have the cable replaced in the walls and have sent new cable, but the contractor they have offered said they can't do the job because the cable was stapled to the studs and they can't do drywall work. So monoprice told me to find someone else on my own to replace the cable and rip up my walls, and rip up a stone fireplace for one of the runs. It has been a nightmare.

Still not sure I will ever buy monoprice cable again for in wall application.
I am literally in the same boat. Thankfully I only used monoprice for 4 POE cameras still working on figuring out the best way to fix it.
Feb 25, 2021 3:41 AM
502 Comments
Joined Mar 2010
lane_meyerFeb 25, 2021 3:41 AM
502 Comments
Quote from danny951 View quoted comment :
I bought and installed 1000' of monoprice cat6 cable in my new home during framing. 6 months later I got a recall notice that the jackets on the cable were not fire rated even though they were marked UL/CL2 or whatever. They are telling me they will pay to have the cable replaced in the walls and have sent new cable, but the contractor they have offered said they can't do the job because the cable was stapled to the studs and they can't do drywall work. So monoprice told me to find someone else on my own to replace the cable and rip up my walls, and rip up a stone fireplace for one of the runs. It has been a nightmare.

Still not sure I will ever buy monoprice cable again for in wall application.
Not sure why this is such a big deal... So you discovered Its not fire retardant... Do you have fires in your house close to the wire? Are you in fear that if your house catches fire and its discovered the wire is not UL then insurance will not pay? Then you should have built a concrete house with metal conduit. Ethernet wire is not a highly combustible item unlike most other building material used in home construction like wood, and asphalt shingles.... If you were that concerned perhaps you should have run metal conduit for all voltage drops including electrical or looked at running plenum cable...
6

Sign up for a Slickdeals account to remove this ad.

Feb 25, 2021 3:44 AM
3.7K Comments
Joined Jul 2013
MitchJFeb 25, 2021 3:44 AM
3.7K Comments
I always wanted to do something like this, but I figured everyone would want to just use wireless. But it sounds like a lot of people on this forum use this kind of thing.

How common would you guys say it is to use stuff like this? Is the frequency of use going up or going down?

Thanks

Join The Conversation

Share your experience with the Slickdeals community

Share information with the community. Please follow our Community Guidelines and be kind!