Pioneer Diamante 9,000 BTU 19 SEER 230V Ductless Mini-Split AC w/ Heat Pump

$678

$1,019

33% off
+ Free Store Pickupat Home Depot
Visit Home Depot
Good Deal?
191Comments
Save
Share
Deal Details
Home Depot has Pioneer Diamante Series 9,000 BTU 19 SEER 230V Ductless Mini-Split Air Conditioner Heat Pump Full Set with 16 Ft. Kit (WYT009GLFI19RL) on sale for $678. Select free store pickup where available.

Thanks to Community Member hugearm for sharing this deal.

Features:
  • Dual Swing
  • Dual Drainage
  • Low Noise
  • High Efficiency
Includes:
  • Indoor Unit
  • Outdoor Unit
  • Wireless Remote Control (with wall holder and batteries)
  • 16 Ft. Copper Lines
  • 16 Ft. Electrical Wire
  • 10 Ft. Drain for indoor/outdoor
  • Wall Passage Sleeve
  • Putty for Wall Hole
  • Leak Guard Sealer
  • Wrapping Tape
  • Installation Manual
  • User's Manual

Editor's Notes

Written by SubZero5 | Staff
  • About this deal:
    • This is $341 lower (34% savings) than the $1,019 list price.
  • About this product:
    • 5-Year Warranty
  • About this store:
    • View Home Depot return policy here.

Original Post

Written by hugearm
Product Info
Community Notes
About the Poster
Deal Details
Product Info
Community Notes
About the Poster
Home Depot has Pioneer Diamante Series 9,000 BTU 19 SEER 230V Ductless Mini-Split Air Conditioner Heat Pump Full Set with 16 Ft. Kit (WYT009GLFI19RL) on sale for $678. Select free store pickup where available.

Thanks to Community Member hugearm for sharing this deal.

Features:
  • Dual Swing
  • Dual Drainage
  • Low Noise
  • High Efficiency
Includes:
  • Indoor Unit
  • Outdoor Unit
  • Wireless Remote Control (with wall holder and batteries)
  • 16 Ft. Copper Lines
  • 16 Ft. Electrical Wire
  • 10 Ft. Drain for indoor/outdoor
  • Wall Passage Sleeve
  • Putty for Wall Hole
  • Leak Guard Sealer
  • Wrapping Tape
  • Installation Manual
  • User's Manual

Editor's Notes

Written by SubZero5 | Staff
  • About this deal:
    • This is $341 lower (34% savings) than the $1,019 list price.
  • About this product:
    • 5-Year Warranty
  • About this store:
    • View Home Depot return policy here.

Original Post

Written by hugearm

Community Voting

Deal Score
+62
Good Deal

Top Comments

Join The Conversation

Share your experience with the Slickdeals community

Share information with the community. Please follow our Community Guidelines and be kind!

191 Comments

Sign up for a Slickdeals account to remove this ad.

Aug 19, 2022 10:50 PM
144 Comments
Joined Jul 2022

This comment has been rated as unhelpful by Slickdeals users.

Aug 20, 2022 12:05 AM
3.8K Comments
Joined Mar 2017
AlexS2465Aug 20, 2022 12:05 AM
3.8K Comments

Our community has rated this post as helpful. If you agree, why not thank

Quote from jabber13713 View quoted comment :
Not necessarily. We are building a room in our detached garage. The existing wiring going into the garage would not allow me to install a 220v without an additional line being added.. we also plan on installing one in our house. It will be much easier to splice into an existing 110v line instead of running an entire new line of 220v from the circuit breaker. The amp draw on these 9000 and 12000 btu units does not need a dedicated line straight from the circuit breaker.
I like when people provide real numbers and NOT educated guess when they say things. By looking specs sheet on these units it shows for 120V minimum Amp line for 9K is 17A and for 12K is 19Amp so that's 20 Amp line or 12GA wire with almost no extra except for few amps draw on top since it will also depend on length of the run as well. For 240V it's half of that obviously due to double voltage. It might be possible to use that line for something else IF it's short run and it doesn't run too often but on start up if Amp draw is higher it will either start overheating wire or trip the breaker. The 14GA/15Amp line is out of the question completely if followed the code.
4
1
Aug 20, 2022 1:11 AM
2.2K Comments
Joined Dec 2013
oahumikeAug 20, 2022 1:11 AM
2.2K Comments

Our community has rated this post as helpful. If you agree, why not thank

Quote from AlexS2465 View quoted comment :
I like when people provide real numbers and NOT educated guess when they say things. By looking specs sheet on these units it shows for 120V minimum Amp line for 9K is 17A and for 12K is 19Amp so that's 20 Amp line or 12GA wire with almost no extra except for few amps draw on top since it will also depend on length of the run as well. For 240V it's half of that obviously due to double voltage. It might be possible to use that line for something else IF it's short run and it doesn't run too often but on start up if Amp draw is higher it will either start overheating wire or trip the breaker. The 14GA/15Amp line is out of the question completely if followed the code.
This. And if you want to be up to code, anything with a compressor of this size should be on its own breaker.
2
Aug 20, 2022 1:30 AM
144 Comments
Joined Jul 2022

This comment has been rated as unhelpful by Slickdeals users.

Aug 20, 2022 1:42 AM
3.8K Comments
Joined Mar 2017
AlexS2465Aug 20, 2022 1:42 AM
3.8K Comments
Quote from jabber13713 View quoted comment :
Educated guess??
Here is the spec sheet for the 110v mini split i purchased

Power Supply (V-Ph-Hz) 115V,1Ph,60Hz
Voltage Range 103.5-126.5
SEER 20.5
EER 12.5
Cooling (Range) 2650~10300
Input (W) 720
Rated current A 6.26
Heating (Range) 2700~10500
Input (W) 1000
Rated Current (A) 8.7
HSPF4 10
HSPF5 7.8
COP W/W 2.93
Minimum Circuit Ampacity (A) 20
Max. Fuse (A) 30

You also have to consider voltage drop for length of wire run, but you didn't mention that at all mr. Know it all..

Also, the connection wiring is 14g, being connected to 12/2 wiring for a 20 amp circuit.. the supplied 14g wiring is the same Guage as 14/2 used in 15amp circuits.. overheating will never be a problem on a protected circuit. If amperage was a problem, they would have used 12g wire on their own product.

Our build isn't finished yet but once this is installed, I will for sure report back on initial startup amp draw as I have multiple tools to measure it.
First I'm NOT "knows it all" just trying to warn that there are differences between "thinking" and what gets accepted/approved by code. Maybe in your county it will be but where I live it won't, so regardless how I'll try to reason with inspector if it's not up the code it won't go anywhere. It's always best to have some power to spare in wiring but again for all I care you can use whatever you want as long as someone following your advice doesn't get in trouble based on that.
1
Aug 20, 2022 3:29 AM
911 Comments
Joined Nov 2007
turningpoint84Aug 20, 2022 3:29 AM
911 Comments
Quote from AlexS2465 View quoted comment :
Why would it be easier install with 120V? The only difference I think would be double instead of single breaker at the panel on the other hand wire to be used can be thinner with 220V.
Maybe he just used an outlet nearby?? Lol
Aug 20, 2022 6:39 AM
144 Comments
Joined Jul 2022

This comment has been rated as unhelpful by Slickdeals users.

Sign up for a Slickdeals account to remove this ad.

Aug 20, 2022 10:31 AM
25 Comments
Joined Nov 2019

This comment has been rated as unhelpful by Slickdeals users.

Aug 20, 2022 12:37 PM
565 Comments
Joined May 2015
WayTooEasyAug 20, 2022 12:37 PM
565 Comments
Quote from SmilingVest5090 View quoted comment :
These are not DIY units. They require specialized equipment that can cost as much as the unit. The lines are not precharged(as far as I can tell) and must be evacuated if you want the system to last and work properly(look up Daltons law of partial pressures). Local ordinances may require you to use a licensed contractor depending on where you live. Also, if something disastrous should happen and your insurance company discovers you DIYed then you will be left to pay yourself.

These should not simply be plugged into the wall. All codes I am aware require you to follow the most restrictive requirement between Federal, State, Local, and Manufacturers instructions.

From the MFG installation instructions:

1. All wiring must comply with local and national electrical codes, and must be installed by a fully licensed electrician.
2. All electrical connections must be made according to the Electrical Connection Diagram located on the side panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work immediately. Explain your reasoning to the client, and suspend all installation of the unit until the safety issue is properly resolved.
4. Power voltage should be within 90-110% of rated voltage. Insufficient power supply can cause electrical shock or fire.
5. Connect power through fixed wiring. Install a surge protector and disconnect switch box. Use a dedicated circuit breaker with a capacity of 1.5 times the maximum current of the unit.
6. A properly rated HACR-type fuse or circuit breaker that disconnects all poles and has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring. The qualified technician must use an approved circuit breaker or switch.
7. Only connect the unit to a dedicated individual branch circuit breaker. Do not connect another appliance to that same circuit.
Geezus, after all the time to type all that bs, you never read any of the product info...

R410A pre-charged outdoor unit, accommodating line lengths up to 25 ft. long
Last edited by WayTooEasy August 20, 2022 at 05:39 AM.
3
Aug 20, 2022 1:24 PM
3 Comments
Joined May 2017
slickeffortAug 20, 2022 1:24 PM
3 Comments
Quote from jmonster View quoted comment :
Because some people don't mind having a wire drop down and plug into a nearby receptacle.

It's not pretty, but it's pretty darn easy
Power supply is installed outdoors.
Aug 20, 2022 1:29 PM
1.8K Comments
Joined Sep 2014
leeterbikeAug 20, 2022 1:29 PM
1.8K Comments
I have one of these in my shop and they're great for locations that vibration and noise isn't a concern as these hum and buzz more than most would like.

Shop area is about 40x80 at 12ft walls with 2 insulated garage doors. Walls,roof, and ceiling are closed cell spray with wood for walls. The unit cools without issue in 100 degree days and keep the shop warm when it's 0 outside.

I've used many units in mini home buildings, Mitsubishi is all I use now as they're quite. These will hum at a frequency that's an annoyance, I would mount the outdoor unit as far as possible from the house and ground mount.
Aug 20, 2022 2:39 PM
172 Comments
Joined Oct 2012
KoholintAug 20, 2022 2:39 PM
172 Comments

Our community has rated this post as helpful. If you agree, why not thank

Do note, the unit is precharged, but the line set needs to be flushed before releasing refrigerant into it.

Pioneer makes this product that makes it easy: https://www.homedepot.com/p/Pione.../314537728
1
Aug 20, 2022 2:49 PM
25 Comments
Joined Nov 2019
SmilingVest5090Aug 20, 2022 2:49 PM
25 Comments
Quote from WayTooEasy View quoted comment :
Geezus, after all the time to type all that bs, you never read any of the product info...

R410A pre-charged outdoor unit, accommodating line lengths up to 25 ft. long
Geezus, maybe you should know what you are talking about before throwing stones. Almost all split AC/HP systems (mini or central) come with a condenser that is precharged with enough refrigerant for a specified length of line set. This refrigerant is held in the outdoor unit ONLY. The line set does not contain a charge most of the time. That is the difference between units like these and the DIY variety(i.e Mr Cool). But what would I know as an HVAC professional with 20 years experience.
1
1
10
Aug 20, 2022 4:18 PM
565 Comments
Joined May 2015
WayTooEasyAug 20, 2022 4:18 PM
565 Comments
Install lines. Open valve. Crack a line open for a sec or two. There. Lines are bled. This isnt rocket science. Works e v e r y time. For those on a budget and dont want to spend some exorbitant amount of money to pay a HVAC professional with 20 years of experience, try it. (unless youre running a line set over 25') Generally, no one has lines that long.
Last edited by WayTooEasy August 20, 2022 at 09:21 AM.
7

Sign up for a Slickdeals account to remove this ad.

Aug 20, 2022 4:39 PM
829 Comments
Joined Nov 2012
OGSDERAug 20, 2022 4:39 PM
829 Comments
Quote from leeterbike View quoted comment :
I have one of these in my shop and they're great for locations that vibration and noise isn't a concern as these hum and buzz more than most would like.

Shop area is about 40x80 at 12ft walls with 2 insulated garage doors. Walls,roof, and ceiling are closed cell spray with wood for walls. The unit cools without issue in 100 degree days and keep the shop warm when it's 0 outside.

I've used many units in mini home buildings, Mitsubishi is all I use now as they're quite. These will hum at a frequency that's an annoyance, I would mount the outdoor unit as far as possible from the house and ground mount.
You use one of these to cool 3200 sq ft?!