25' Sun Joe 10/3-Gauge 3-Way Split 3750W Generator Series Extension Cord

+ Free Shipping

$35

$99

64% off
Amazon
28 Comments 39,203 Views
Visit Amazon
Good Deal
Save
Share
Deal Details
Amazon has 25' Sun Joe 10/3-Gauge 3-Way Split 3750W Generator Series Extension Cord (SJG-EXT2510-3WAY) on sale for $34.78. Shipping is free.

Thanks to Deal Hunter niki4h for sharing this deal.

About this Item:
  • 10/3 gauge
  • Featuring one L5-30P plug and three 5-20R receptacles
  • Resistant to temperatures between -13º F – 221º F
  • Max output of 3750 watts
  • Grounded cord with individual 20 A circuit breakers
  • Features a convenient storage strap + carrying handle

Editor's Notes

Written by citan359 | Staff
  • About this deal:
    • Our research indicates that this deal is $16.59 less (32% savings) than the next best available price from a reputable merchant with prices starting from $51.37 at the time of this posting.
  • About this store:
  • Additional Note:
    • Please refer to the Forum Thread for additional discussion regarding this deal.

Original Post

Written by niki4h | Staff
Product Info
Community Notes
About the Poster
Deal Details
Product Info
Community Notes
About the Poster
Amazon has 25' Sun Joe 10/3-Gauge 3-Way Split 3750W Generator Series Extension Cord (SJG-EXT2510-3WAY) on sale for $34.78. Shipping is free.

Thanks to Deal Hunter niki4h for sharing this deal.

About this Item:
  • 10/3 gauge
  • Featuring one L5-30P plug and three 5-20R receptacles
  • Resistant to temperatures between -13º F – 221º F
  • Max output of 3750 watts
  • Grounded cord with individual 20 A circuit breakers
  • Features a convenient storage strap + carrying handle

Editor's Notes

Written by citan359 | Staff
  • About this deal:
    • Our research indicates that this deal is $16.59 less (32% savings) than the next best available price from a reputable merchant with prices starting from $51.37 at the time of this posting.
  • About this store:
  • Additional Note:
    • Please refer to the Forum Thread for additional discussion regarding this deal.

Original Post

Written by niki4h | Staff

Community Voting

Deal Score
+31
Good Deal
Visit Amazon

Price Intelligence

Model: Sun Joe 25-ft Heavy Duty Extension Cord for Use w/ Generator

Deal History 

Sale Price
Slickdeal
  • $NaN
  • Today

Current Prices

Sort: Lowest to Highest | Last Updated 7/2/2025, 12:40 AM
Sold By Sale Price
Amazon$36.99

Leave a Comment

Unregistered (You)

Top Comments

RonPaulFan
1730 Posts
481 Reputation
30A 120V locking plug to (3) 20A 120V plugs.

Not 30A 240v locking plug to (3) 20A 120V plugs
TodayOnly
9172 Posts
1501 Reputation
according to google search this ranges from $35 to $100 at various retailers. avg price being around $50.

27 Comments

Sign up for a Slickdeals account to remove this ad.

Jun 4, 2023
3,418 Posts
Joined Nov 2011
Jun 4, 2023
timbertop
Jun 4, 2023
3,418 Posts
Quote from TodayOnly :
yup, just checked return window and right under the 30 days!

im still learning all about generators and right now i have no plans to wire in a transfer switch and buy a huge generator. id rather have 2 or even 3 smaller generators.

neighbors would absolutely love me with 3 fired up around the house and probably show up with their own extension cords in hand! laugh out loud
When using extension cords in a power outage where there is no transfer switch this 30 amp split-er cord is perfect. One heavy 10 ga cord to bring the power inside from the generator's 30 amp 120V outlet then use 3 x 12 ga cords to run out to the fridge and to other rooms where you need temporary power. For $35 this deal cord provides precisely the needed solution. Even if folks only have the 30 TT receptacle on their 120V generator they should get this for outages.
Jun 4, 2023
9,172 Posts
Joined Aug 2018
Jun 4, 2023
TodayOnly
Jun 4, 2023
9,172 Posts
Quote from timbertop :
When using extension cords in a power outage where there is no transfer switch this 30 amp split-er cord is perfect. One heavy 10 ga cord to bring the power inside from the generator's 30 amp 120V outlet then use 3 x 12 ga cords to run out to the fridge and to other rooms where you need temporary power. For $35 this deal cord provides precisely the needed solution. Even if folks only have the 30 TT receptacle on their 120V generator they should get this for outages.
Yup, this is exactly what i plan on doing. this 10/3 3-split into the garage and to a 12/3 cord into the house for a heater or some kind of small portable AC.
Jun 4, 2023
3,418 Posts
Joined Nov 2011
Jun 4, 2023
timbertop
Jun 4, 2023
3,418 Posts
Quote from TodayOnly :
Yup, this is exactly what i plan on doing. this 10/3 3-split into the garage and to a 12/3 cord into the house for a heater or some kind of small portable AC.
For those with 120/240V generators which have a L14-30R 120/240 volt receptacle use a L14-30 adapter extension cord as the temporary main power entry to the structure. https://www.amazon.com/dp/B08GH5N2LF/
This one terminates to two pairs of 20A standard receptacles with each pair connected to one side of the 240 V generator's two 120 volt circuits.

L14-30 adapter type cord sets should split to the loads as above across the generator's two 120 V legs. This way the full load on the generator is balanced just as it is when the L14 is wired to the balanced house panel via the transfer switch. Users must make the effort to balance out the loads connected to each 120 V side of the 4 wire extension cord, for example one 15 amp heater per outlet.

Instead of making use of the 30 amp outlet on the generator most inexperienced users run multiple 14 or 16 ga extension cords out the generator and plug them in to the duplex outlets on the generator. This increases the chance of overload, fire and equipment damage. Voltage drop will occur with the light duty extension cords.
Jun 4, 2023
9,172 Posts
Joined Aug 2018
Jun 4, 2023
TodayOnly
Jun 4, 2023
9,172 Posts
Quote from timbertop :
For those with 120/240V generators which have a L14-30R 120/240 volt receptacle use a L14-30 adapter extension cord as the temporary main power entry to the structure. https://www.amazon.com/dp/B08GH5N2LF/
This one terminates to two pairs of 20A standard receptacles with each pair connected to one side of the 240 V generator's two 120 volt circuits.

L14-30 adapter type cord sets should split to the loads as above across the generator's two 120 V legs. This way the full load on the generator is balanced just as it is when the L14 is wired to the balanced house panel via the transfer switch. Users must make the effort to balance out the loads connected to each 120 V side of the 4 wire extension cord, for example one 15 amp heater per outlet.

Instead of making use of the 30 amp outlet on the generator most inexperienced users run multiple 14 or 16 ga extension cords out the generator and plug them in to the duplex outlets on the generator. This increases the chance of overload, fire and equipment damage. Voltage drop will occur with the light duty extension cords.
i noticed this when i was looking at regular 10/3 cords and their max amp/watts. this 10/3 3-way cord can do almost 3 times a regular cord since its plugged into the 30 amp twist/lock outlet.
Jun 4, 2023
3,418 Posts
Joined Nov 2011
Jun 4, 2023
timbertop
Jun 4, 2023
3,418 Posts
Quote from TodayOnly :
i noticed this when i was looking at regular 10/3 cords and their max amp/watts. this 10/3 3-way cord can do almost 3 times a regular cord since its plugged into the 30 amp twist/lock outlet.
Not quite. It should be able to handle 30 amps instead of the 20 amps or less of a common extension cord. 10 ga, 25 ft and the 30 amp input connector gives the amp rating . 3 x 125 volts for the receptacles =3750 watts mentioned. I wonder why the listing for this Joe cord states that the input is only 20 amps. I will look for its certifications and markings when it arrives. Note that the four conductor L14-30 split-er cord is rated 7500 watts due to the extra 125 volt circuit.

If it is at all possible to manage a permanent wire run from the house load center to a generator inlet outside the structure that is the way to go. Homeowners can do the work and have an electrician make the final connection for a reasonable cost.
Jun 4, 2023
72 Posts
Joined Nov 2020
Jun 4, 2023
AmusedWalrus629
Jun 4, 2023
72 Posts
Quote from WiseApparel228 :
Connector Gender Male-to-Female
Now you're talking.
In that case, Happy Pride Month! 🌈⚧️
2
Jun 4, 2023
941 Posts
Joined Jun 2006
Jun 4, 2023
Masked Marvel
Jun 4, 2023
941 Posts
Gonna be great looking at my new cable and badass generator while I still have power and all the neighbors are dark.

#whattodotoneverlosepower
1

Sign up for a Slickdeals account to remove this ad.

Jun 6, 2023
224 Posts
Joined Oct 2008
Jun 6, 2023
ek9cusco
Jun 6, 2023
224 Posts
stupid question, but figured better to ask to be sure. i have a Firman 3200W Running / 4000W Peak Dual Fuel Inverter Generator (from Costco), would this SunJoe max 3750 watts would not be safe to use if running at 4KW peak?
Jun 7, 2023
9,172 Posts
Joined Aug 2018
Jun 7, 2023
TodayOnly
Jun 7, 2023
9,172 Posts
received cable today. despite it being shipped in an amazon shipping box the cable box looked like it had been around the world a couple of times. the cable inside is brand new though. laugh out loud
Jun 8, 2023
3,418 Posts
Joined Nov 2011
Jun 8, 2023
timbertop
Jun 8, 2023
3,418 Posts
Price has dropped to $31.30 June 8 at 9 am PDT Great price for a 10 gauge power cord even if you need to change out the L5-30 plug.

Quote from ek9cusco :
stupid question, but figured better to ask to be sure. i have a Firman 3200W Running / 4000W Peak Dual Fuel Inverter Generator (from Costco), would this SunJoe max 3750 watts would not be safe to use if running at 4KW peak?
Yes and no. This cord is for your generator if it has the L5-30r outlet.

Your operating or running wattage can't exceed 3200 watts according to the spec which you give. Check the specification for generator running amps. Check the generator breaker amps. Do not exceed the lower of two amp ratings.

Peak wattage aka "Chinese Watts" and peak amps are only for a few seconds when a motor starts which will not cause a problem with overheating the power cord.

Generators work best and have the longest life at 70% of the rated output which is 2240 watts in this case. Note that generator ratings are given at 70F and at sea level. When ambient temperature rises or the generator is used at elevation the available power is less. In these conditions use 50% of rated watts ( 1600 watts here ) as your target unless the operation is intermittent.

Respectable generator manufacturers never use "peak watts" to describe their product. It is a dishonest and confusing rating. Westinghouse and Briggs are one of the few Chinese brands which advertise running not peak watts. i.e. wgen5300 = 5300 watt generator wgen7500 = 7500 watt generator. Amazon recently started listing these by peak wattage.
Jun 8, 2023
883 Posts
Joined Oct 2003
Jun 8, 2023
Tank
Jun 8, 2023
883 Posts
LoL just received mine from Amazon. It is a returned item from someone else. Amazon put the original box of the cable with the previous shippers address in a bigger box and selling it as new...
1