Slickdeals is community-supported.  We may get paid by brands or deals, including promoted items.
Sorry, this deal has expired. Get notified of deals like this in the future. Add Deal Alert for this Item
Frontpage

Prime Members: X-Sense XS01-WX Wi-Fi Smoke Alarm Expired

$20
$39.99
+ Free Shipping
+22 Deal Score
28,825 Views
X-Sense US via Amazon offers Prime Members: X-Sense XS01-WX Wi-Fi Smoke Alarm on sale for $19.99. Shipping is free.

Thanks to community member SlickAP for finding this deal.

Product Details:
  • Wi-Fi Connection: Simply connect your alarm to the X-Sense app via a 2.4 GHz Wi-Fi network to remotely control it.
  • Self-Check Function: The alarm auto-checks its battery, sensor, and electronics every 60 seconds to ensure proper functioning.
  • Real-Time Notifications: You will receive real-time alerts directly to your smartphone any time a fire starts and the alarm is triggered.
  • Silence at Your Fingertips: Tap the button in the app to silence any alarms without the need to climb a ladder to reach the test/silence button.
  • An insect-proof mesh isolates the sensor from insect interference for accurate, responsive detection.
  • This detector has a slim, contemporary design that can be mounted discreetly on any wall or ceiling.
  • As the battery gets weak, a low battery warning will let you know that it needs to be replaced.
  • 1-Year Warranty / 10-Year Operational Life

Original Post

Written by
Edited October 16, 2023 at 06:10 AM by
X-Sense Smart Smoke Detector Fire Alarm with Replaceable Battery for $19.99 on Amazon [amazon.com]
Prime Exclusive Deal
If you purchase something through a post on our site, Slickdeals may get a small share of the sale.
Deal
Score
+22
28,825 Views
$20
$39.99

Price Intelligence

Model: X-Sense Smart Smoke Detector Fire Alarm with Replaceable Battery, Wi-Fi Smoke Detector, App Notifications with Optional 24/7 Professional Monitoring Service, XS01-WX, 1-Pack

Deal History 

Sort: Most Recent
Post Date Sold By Sale Price Activity
05/06/24Amazon$19.99
0
11/20/23Amazon$20
6
Don't have Amazon Prime? Students can get a free 6-Month Amazon Prime trial with free 2-day shipping, unlimited video streaming & more. If you're not a student, there's also a free 1-Month Amazon Prime trial available. You can also earn cash back rewards on Amazon and Whole Foods purchases with the Amazon Prime Visa credit card. Read our review to see if it’s the right card for you.

Your comment cannot be blank.

Featured Comments

There are a lot of people who recommend photoelectric (only) smoke detectors. The problem with ionization detectors is they cause a lot of nuisance alarms - and that results in people disconnecting them - either removing batteries from detectors that aren't hard wired, or doing that plus disconnecting hard wired ones.
Here's one clear explanation of the issue: structuretech.com/smoke-alarms-deadly-differences/ (This has a few links to more info at the end of the article.)
https://structuretech.com/wp-cont...-03_11.pdf
http://www.consumerreports.org/ho...106391645/

You could also have mostly photoelectric, but put one or two ionization (or dual) alarms in places where they're not likely to cause nuisance alarms (moisture/smoke in kitchen, and bathroom moisture (in a hallway near the bathroom) can cause the nuisance alarms). The problem with this is that if you have hard-wired alarms, you need to have all the same alarms connected to that system, because having different ones connected in the system can cause their own problems (including nuisance alarms). A way around this is to put photoelectric-only in the system, but buy a battery operated ionization to have outside the system.

Manufacturers are supposed to be developing better detectors that reduce nuisance alarms (was first supposed to be implemented in 2019, but that got delayed; as I understand it, that will involve a different technology so these (when available) will not be labeled as photoelectric and/or ionization). Underwriters Limited developed a new standard, but implementation of that has be postponed several times already. There was a Kidde that initially claimed to meet this newest UL 217 standard (the new standard is UL 217, 8th edition; currently, smoke alarms being sold must meet the 7th edition), but Kidde stopped making that claim, and has no detectors currently that meet it. It seems manufacturers are struggling to meet this standard. (There is a less common manufacturer or two that claimed to meet the newer standard but when I looked at reviews a while ago, I wasn't convinced they were a quality product). Brief overview of 8th edition standard: http://incompliancemag.com/eighth...oke-alarm/, http://www.intertek.com/life-safe...h-edition/

===
I personally don't like the ones with the (supposedly) 10 year lithium battery - if you look at reviews, those batteries fail quite often in under 10 years - and I had this happen with some I purchased. I guess in some places, you can't buy anything else legally, but I'm luckily not in one of those places. Keep your receipt and the box if you buy these, and read the warranty, then try to make a warranty claim if the batter/detector fails.

As a note, manufacturers tend to be very misleading about which edition of the UL 217 standard they meet - often, they just say they meet UL 217 (but not which edition). To make that claim, they need to meet the standard in effect at time of manufacture, but smoke detectors that meet earlier standards can continue to be sold after the current standard is updated, so pay attention to the date of manufacture.

If you live in an area with Menards, they sell a very reasonably priced Kidde photoelectric-only smoke alarm, a little under $15. Ionization alarms tend to be cheaper than photoelectric or dual.

I personally purchase CO detectors as separate items. The digital Nighthawk, that plugs in AND operates with a battery, is my choice. It keeps track of any CO levels over 10 PPM - you can press the peak level button to see that (and reset it to zero. It won't alarm unless the level goes over 50 PPM for a certain amount of time. If you check the peak level every once in a while you may detect a problem problem that isn't yet serious enough to cause an alarm (note that natural gas stoves if not working properly or if they're not vented can generate these lower levels of CO in your house - that can cause health issues and mild headaches, especially for more sensitive or older people or people with respiratory issues.).

Unfortunately, even Underwriter Limited doesn't have really clear info about the new standard and when it's now supposed to be implemented easily found on its website - here are a few links:
ww.ul.com/news/smoke-alarms-and-smoke-detectors-new-and-revised-requirements
http://www.ul.com/news/news-brief...ufacturers

Amazon prices on smoke detectors & CO detectors may go down around Black Friday/cyber monday sales.

Note that you should carefully vacuum around smoke and CO detectors at least a few times annually - maybe even monthly. Dust and bugs and spider webs can all lead to nuisance alarms or failure.

Keep your receipt and info about the warranty - you can make a warranty claim if they fail before they're supposed to. If date of manufacturer is stamped on them (I believe that is now required), you can probably make a warranty claim even if you don't have proof of when you purchased it - but they'll probably start counting the time from date of manufacture rather than date of purchase. You'll likely get a replacement unit, not money refunded.

==
In case anyone has one of these (not-so-common) brands: CPSC Warns Consumers to Immediately Stop Using GLBSUNION and CUZMAK Digital Display Carbon Monoxide Detectors (does not detect CO) - were sold on Amazon; recall from March 2023 http://www.cpsc.gov/Newsroom/News...Amazon-com

Sign up for a Slickdeals account to remove this ad.

Joined Jun 2006
L8: Grand Teacher
> bubble2 3,253 Posts
579 Reputation
DAC21
10-16-2023 at 04:50 PM.
10-16-2023 at 04:50 PM.
Quote from elefante72 :
NYS does and while they do not do yearly inspections every time you get work done or do a permit (I mean legally) they will require you for costly upgrades. I think a year or two ago they now require lithium versions that kill themselves after 10 years. I wonder who lobbied for these customer-friendly changes.

Ironically even if you have hard wired detectors they also want the new lithium ones. I argued for some time on that and told them the CO2 was not hard wired (and it was).

They also require ones (at least in bedrooms) to be tied together.

I feel wifi versions are hilarious. If the power goes off or if there is a fire and your wifi goes off I guess it becomes useless if you don't have full battery backup in the alert chain.

I just stick w/ old school vista 20 panel and hardwired.

Stupid state, I would check if you can tie these together--else they probably run afoul of NYS latest regs.

I'm not against noname Chinese companies but this is a highly regulated industry, and the last thing is I want the state or worse the insurance company to come up w/ some reason not to pay out so I would check w/ your local jurisdiction first before buying this stuff.
"I feel wifi versions are hilarious. If the power goes off or if there is a fire and your wifi goes off I guess it becomes useless if you don't have full battery backup in the alert "

That is true as well for tens of million of hardwired smoke detectors that don't have battery back up. Power goes out you do get a chirp or two which "might" wake people up, but thats it. This wifi smoke detector is battery operated. It will still have an alarm in case of a fire and if there's no power it just won't be able to push the notification out if you are not home. Hardly worthless.
Like
Funny
>
Helpful
Not helpful
Reply
Last edited by DAC21 October 16, 2023 at 04:54 PM.
Joined Oct 2013
L8: Grand Teacher
> bubble2 3,357 Posts
637 Reputation
Expert
This user is an Expert in Home & Home Improvement
wherestheanykey
10-16-2023 at 05:09 PM.
10-16-2023 at 05:09 PM.
Quote from VioletCaption5716 :
Worst case you could create an instance in Home Assistant, then pair Home Assistant with Google Home. But this solution is combersome and requires maintenance and $.

I used to have a very complicated Home Assistant setup and have considered picking up a Hubitat.

Google has been improving their automation capability lately, so I'm trying to see how far I can get with native solutions.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Apr 2018
L6: Expert
> bubble2 1,638 Posts
167 Reputation
krnprogamer
10-16-2023 at 05:40 PM.
10-16-2023 at 05:40 PM.
Quote from louweed :
At that price should have carbon monoxide detector 👎🏼
For just the smoke dector, I agree. Not having a combo detector in your home is death wish anyways. Unless you have a home without a single gas appliances/HVAC.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Jan 2022
L3: Novice
> bubble2 260 Posts
54 Reputation
VioletRaccoon567
10-16-2023 at 05:56 PM.
10-16-2023 at 05:56 PM.
Are these interconnected with voice announcements?
Like
Funny
>
Helpful
Not helpful
Reply
Joined Feb 2017
L7: Teacher
> bubble2 2,858 Posts
923 Reputation
Redmont
10-17-2023 at 04:05 AM.
10-17-2023 at 04:05 AM.
Quote from EliasE9448 :
The state requires that in your own house? Do they come to inspect your home every year?
Welcome to progressive hell. If there is a fire and the fire department finds that you disconnected your hardwired smoke alarms you will be fined or arrested and if you want to rent or sell your home you will need a certificate from the fire department that your smoke and CO2 detectors are connected and working.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Feb 2017
L7: Teacher
> bubble2 2,858 Posts
923 Reputation
Redmont
10-17-2023 at 04:08 AM.
10-17-2023 at 04:08 AM.
Quote from Panderbear8 :
You might talk to the inspection department and possibly get away with (1) wired smoke detector and the remaining wireless.
It is not up to them— it's the law. As usual the laws do not keep up with technology and common sense has no place in enforcing outdated laws.
Like
Funny
>
Helpful
Not helpful
Reply
Page 5 of 5
Start the Conversation
 
Link Copied

The link has been copied to the clipboard.