https://www.homedepot.com/p/Pione.../326231266 - YMMV, stock and price may vary by location

This unit has received good reviews in the past, been waiting for it to go on sale again.
If you purchase something through a post on our site, Slickdeals may get a small share of the sale.
Deal
Score
+27
46,501 Views
$652.00
$834.00

Community Wiki

Last Edited by MxChris May 17, 2024 at 07:41 PM
They've marked it OOS/raised the price on the website but you can still get it for the lower price if you call.

Ask them to search for the Model # WYT012GLFI19RL on the website and they will see two results, one at $768 and one for $645.48 same item, they will adjust the price for you. Online Customer Support: 800-466-3337, select place an order in the menu.

============

Check and see if you'll qualify for a rebate on this unit. In FL I will get $150.

https://www.pioneerminisplit.com/...WgQAvD_BwE

Your comment cannot be blank.

Sign up for a Slickdeals account to remove this ad.

This comment has been rated as unhelpful by Slickdeals users

Show Comment
Joined Jun 2022
L5: Journeyman
> bubble2 562 Posts
67 Reputation
DillDozer
05-11-2024 at 12:41 PM.
05-11-2024 at 12:41 PM.
Quote from Spook52 :
The ebay unit does look similar. It doesn't appear to be low ambient though.

It's identical (only difference is lineset insulation is cheap). Documentation on generic stuff is lacking and incorrect a lot of times. Heated with no issue when -8F last winter.

Talking about windows....
I installed three of these into windows on a 3 floor townhouse. Screwed the bracket to the frame, ran lineset and power through windows, ta da!
And since it's temporary, you can take it with when you leave with no holes in the wall.
1
Like
Funny
>
Helpful
Not helpful
Reply
Last edited by DillDozer May 11, 2024 at 12:45 PM.
Joined May 2016
L5: Journeyman
> bubble2 806 Posts
169 Reputation
Spook52
05-11-2024 at 01:44 PM.
05-11-2024 at 01:44 PM.
Quote from DillDozer :
It's identical (only difference is lineset insulation is cheap). Documentation on generic stuff is lacking and incorrect a lot of times. Heated with no issue when -8F last winter.

Talking about windows....
I installed three of these into windows on a 3 floor townhouse. Screwed the bracket to the frame, ran lineset and power through windows, ta da!
And since it's temporary, you can take it with when you leave with no holes in the wall.
Thanks for the tip! I'll check it out. Much appreciated.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2005
Tuxfan
> bubble2 2,366 Posts
692 Reputation
minghi
05-11-2024 at 08:47 PM.
05-11-2024 at 08:47 PM.
Quote from DillDozer :
It's $495 on eBay every day for same unit with zokop badging. Pioneer just marks up midea units.
120V available, too.

Cheaper at $436 on HD

https://www.homedepot.com/p/9000-.../328867250
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Feb 2016
L2: Beginner
> bubble2 83 Posts
10 Reputation
Galahad21
05-11-2024 at 10:46 PM.
05-11-2024 at 10:46 PM.
Quote from AmusedDime497 :
I'm just here for the how hard are these to install comments 🍿🥤

Not hard at all
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2019
L5: Journeyman
> bubble2 516 Posts
42 Reputation
jrricky
05-11-2024 at 11:18 PM.
05-11-2024 at 11:18 PM.
Quote from DillDozer :
It's identical (only difference is lineset insulation is cheap). Documentation on generic stuff is lacking and incorrect a lot of times. Heated with no issue when -8F last winter.

Talking about windows....
I installed three of these into windows on a 3 floor townhouse. Screwed the bracket to the frame, ran lineset and power through windows, ta da!
And since it's temporary, you can take it with when you leave with no holes in the wall.

Wait what?
Like
Funny
>
Helpful
Not helpful
Reply
Joined Oct 2017
L3: Novice
> bubble2 267 Posts
46 Reputation
DanL6043
05-12-2024 at 03:00 AM.
05-12-2024 at 03:00 AM.
Quote from jrricky :
Wait what?
They mean after running 220 circuits and hanging it on a balcony or outside wall and drilling 3 to 4 inch holes through the walls Smilie At least it seems to be pre-charged.
Like
Funny
>
Helpful
Not helpful
Reply

Sign up for a Slickdeals account to remove this ad.

Joined Oct 2017
L3: Novice
> bubble2 267 Posts
46 Reputation
DanL6043
05-12-2024 at 03:04 AM.
05-12-2024 at 03:04 AM.
This is a good deal for a decent unit plus low temp heating. Kinda of surprised the SEER rating isn't better. It is somewhat DIY in that the unit is precharged however the line set is not so you still need to evacuate the lines so a vacuum pump process is needed. It's not plug and play like EG4, Mr. Cool, Denali Aire, Perfect Aire, etc.
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Nov 2005
Tuxfan
> bubble2 2,366 Posts
692 Reputation
minghi
05-12-2024 at 03:57 AM.
05-12-2024 at 03:57 AM.
Quote from DanL6043 :
This is a good deal for a decent unit plus low temp heating. Kinda of surprised the SEER rating isn't better. It is somewhat DIY in that the unit is precharged however the line set is not so you still need to evacuate the lines so a vacuum pump process is needed. It's not plug and play like EG4, Mr. Cool, Denali Aire, Perfect Aire, etc.

I installed a similar pioneer unit last year using this to evacuate the lines and it worked great.

https://www.homedepot.com/p/Pione.../314537728
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Sep 2023
L2: Beginner
> bubble2 43 Posts
10 Reputation
FeistyHalibut688
05-12-2024 at 04:22 AM.
05-12-2024 at 04:22 AM.
Quote from minghi :
I installed a similar pioneer unit last year using this to evacuate the lines and it worked great.

https://www.homedepot.com/p/Pione.../314537728

That's not what evacuating means. Evacuating means pulling a vacuum on the system/lineset to less than 500 microns. Moisture(yes, even the humidity in the air) is not good for your system. As the moisture passes over the compressor windings some sciencey electrolysis stuff happens causing acid eventually eating up the insulation on the windings. Hopefully these things come with a drier to help catch what you missed. A pressure test is also better than a vacuum test. A pressure test with nitrogen will get you to operating pressures(350+psi) where a vacuum test is the equivalent of something like -16psi. A micron gauge can help with this a bit but I've had leaks show up at 275psi that weren't present at 225psi.
Like
Funny
>
Helpful
Not helpful
Reply
Joined May 2016
L5: Journeyman
> bubble2 806 Posts
169 Reputation
Spook52
05-12-2024 at 05:14 AM.
05-12-2024 at 05:14 AM.
Quote from FeistyHalibut688 :
That's not what evacuating means. Evacuating means pulling a vacuum on the system/lineset to less than 500 microns. Moisture(yes, even the humidity in the air) is not good for your system. As the moisture passes over the compressor windings some sciencey electrolysis stuff happens causing acid eventually eating up the insulation on the windings. Hopefully these things come with a drier to help catch what you missed. A pressure test is also better than a vacuum test. A pressure test with nitrogen will get you to operating pressures(350+psi) where a vacuum test is the equivalent of something like -16psi. A micron gauge can help with this a bit but I've had leaks show up at 275psi that weren't present at 225psi.
Pioneer KWIK-E-VAC is an all-new, revolutionary, patented kit designed to simplify the installation process. This product is intended to provide an alternative to a vacuum pump, a tool that was previously required to install mini splits. KWIK-E-VAC works by flushing the air and other non-condensable gases out of the copper line set and indoor unit combination, in order to ensure that the refrigerant in the system remains contaminant-free. In order to bleed the lines of any air and check for leaks, a vacuum pump and pressure gauges were previously needed. This kit allows the user to bypass that step, making any mini-split system truly DIY. Use this as an alternative for the inefficient and expensive quick-connect line sets, which reduce system efficiency and capacity, and cost 10 times more than the cost of this kit. A cost-effective, simple, and quick evacuation, perfect for most people and installations.
4
Like
Funny
>
Helpful
Not helpful
Reply
Joined May 2016
L5: Journeyman
> bubble2 806 Posts
169 Reputation
Spook52
05-12-2024 at 05:15 AM.
05-12-2024 at 05:15 AM.
Quote from minghi :
I installed a similar pioneer unit last year using this to evacuate the lines and it worked great.

https://www.homedepot.com/p/Pione.../314537728
I used a vacuum pump last time, but that can seems like it would have been a good option.
Like
Funny
>
Helpful
Not helpful
Reply
Joined Jan 2017
L3: Novice
> bubble2 108 Posts
10 Reputation
Obiwan_Stormblessed
05-12-2024 at 05:25 AM.
05-12-2024 at 05:25 AM.
I'm all for a slick deal but when it comes to these units we just stick with Daikin. It is the best quality for the money. If you are going to go to the effort of installing one of these in a garage, man cave, or bonus room get something that will work.
1
Like
Funny
>
Helpful
Not helpful
Reply
Joined Apr 2011
L2: Beginner
> bubble2 89 Posts
14 Reputation
Hagans79
05-12-2024 at 07:52 AM.
05-12-2024 at 07:52 AM.
Quote from AmusedDime497 :
I'm just here for the how hard are these to install comments 🍿🥤

Are they hard to install? Or can I watch a YouTube video?
Like
Funny
>
Helpful
Not helpful
Reply

Sign up for a Slickdeals account to remove this ad.

Joined Oct 2011
L6: Expert
> bubble2 1,777 Posts
215 Reputation
funkadunk8
05-12-2024 at 07:53 AM.
05-12-2024 at 07:53 AM.
Only works down to -13f whereas a true cold climate like senville is still 75% output at -22f, just fyi